Key result
Experiencing an ICD shock was associated with having an active device at death (62.5%), whereas 93.7% of patients who had their ICD deactivated never experienced a shock (p=0.003).
Population
44 deceased patients with an implantable cardioverter defibrillator whose medical notes were retrieved from…
Design
Cohort
Authors
Loading...
Supports targeted deactivation education in ICD patients; hypothesis-generating for factors influencing end-of-life decisions.
Observational (n=44)
No
p-value: p=0.003
Patients with ICDs are inadequately informed about device deactivation at the end of life, highlighting a significant gap between clinical guideline recommendations and real-world practice.
Hill et al. (2015) conducted an observational in Patients with an implantable cardioverter defibrillator (ICD) (n=44). Experience of an ICD shock vs. No experience of an ICD shock was evaluated on Active ICD at death vs deactivated ICD (p=0.003). Experiencing an ICD shock was associated with having an active device at death (62.5%), whereas 93.7% of patients who had their ICD deactivated never experienced a shock (p=0.003).