Key result
Increasing the stimulus strength of left ventricular pacing to 5 V in patients with cardiac resynchronization therapy significantly reduced QRS duration and improved left ventricular ejection fraction compared to standard 2.5 V pacing.
Why the study?
Does increasing stimulus strength of left ventricular pacing improve LV mechanical dyssynchrony and cardiac function in patients treated with CRT?
Does increasing stimulus strength of left ventricular pacing improve LV mechanical dyssynchrony and cardiac function in patients treated with CRT?
Answers are grounded in this paper and cite their sources.
Increasing the stimulus strength of left ventricular pacing to 5 V in CRT patients acutely improves LV mechanical dyssynchrony and cardiac function.
Cardiac resynchronization therapy (CRT) is an established therapy in patients with severe heart failure due to left ventricular (LV) dyssynchrony. Increasing stimulus strength (SS) of LV pacing could capture an enlarged myocardial area and provide rapid electrical conduction. The aim of the present study was to investigate whether increasing SS of LV pacing improves LV mechanical dyssynchrony and cardiac function in patients treated with CRT.We enrolled 26 patients with CRT and changed the SS of LV pacing: 2.5 V (standard SS) and 5 V (high SS). Electrocardiography and echocardiography were performed to assess QRS duration, LV mechanical dyssynchrony, and cardiac function under each condition.The QRS duration (138.6 ± 21.4 ms versus 126.8 ± 23.1 ms, P < 0.001), septal-posterior wall motion delay (126.5 ± 42.7 ms versus 111.4 ± 55.3 ms, P = 0.012), standard deviation of time from QRS (69.6 ± 21.8 ms versus 55.6 ± 19.4 ms, P < 0.001), LV ejection fraction (29.4 ± 10.6% versus 33.4 ± 11.6%, P = 0.005), and LV stroke volume (50.7 ± 15.5 mL versus 63.8 ± 18.3 mL, P < 0.001) improved significantly in high SS compared with standard SS.Increasing SS of LV pacing in CRT improves LV mechanical dyssynchrony and cardiac function. The capture of an enlarged myocardial area by increasing SS of LV pacing might offer an acute hemodynamic benefit to patients treated with CRT.
No takes yet. Share an insight, caveat, or question.
Ishibashi et al. (2014) studied Severe heart failure with left ventricular dyssynchrony (n=26). High stimulus strength (5 V) of left ventricular pacing vs. Standard stimulus strength (2.5 V) was evaluated on QRS duration (p=<0.001). Increasing the stimulus strength of left ventricular pacing to 5 V in patients with cardiac resynchronization therapy significantly reduced QRS duration and improved left ventricular ejection fraction compared to standard 2.5 V pacing.
Synapse has enriched 10 related papers. Consider them for comparative context: