Experimental and numerical study demonstrates vibration propagation patterns in an integrated fracturing vessel, indicating optimal startup sequences and layout configurations.
This study investigates vibration propagation from a single fracturing pump in a large-scale integrated fracturing vessel. Vibration testing is performed on an SCF5000 electric-driven fracturing skid to measure vibration acceleration levels (VALs) at various motor speeds. A finite element model of the fracturing cabin system is developed to analyze motion and stress fields under both harmonic and measured excitations. Results indicate that VALs across the skid base remain uniform (Coefficient of Variation (CoV) < 10%), except at two locations influenced by the motor’s large mass. VALs increase by 51% as the speed increases from 600 to 2100 rpm, with vibration energy shifting toward higher frequencies. Motion responses, such as vertical displacement (VD) and vertical acceleration (VA), attenuate in an approximately half-sinusoidal pattern, with VA amplification near the active pump reaching about 126%. An optimal startup sequence (edge pumps first, central pump last) is proposed. Under measured excitations, peak VD, VA, and deck stress increase on average by 18% with rising speed. The layout scheme with a smaller deck span and a 2–3 pump distribution is identified as superior. This study provides a validated framework for vibration control and equipment arrangement in fracturing vessels.
No takes yet. Share an insight, caveat, or question.
WANG et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: