Key result
Percutaneous implantation of a 4-mm atrial flow regulator device in a 4-year-old male with a failing Fontan circulation increased oxygen saturation from 75% to 95% at 2 months.
Why the study?
Does percutaneous implantation of an atrial flow regulator improve oxygen saturation and reduce right-to-left shunting in a pediatric patient with severe cyanosis following a fenestrated Fontan procedure?
Case Report (n=1)
Does percutaneous implantation of an atrial flow regulator improve oxygen saturation and reduce right-to-left shunting in a pediatric patient with severe cyanosis following a fenestrated Fontan procedure?
Absolute Event Rate: 95% vs 75%
Percutaneous implantation of an atrial flow regulator may be an effective compassionate use strategy to improve oxygen saturation and reduce right-to-left shunting in patients with a failing fenestrated Fontan circulation.
May support compassionate use in failing Fontan cyanosis; hypothesis-generating and requires prospective validation.
Transcatheter creation or enlargement of an atrial septal defect has been used to promote adequate blood flow and mixing in some forms of congenital heart defects or as a relief valve in right or left atrial hypertension, resulting in better cardiac output and/or systemic saturation. We report a case of a 4-year-old male affected by complex congenital heart disease who was admitted for management of severe cyanosis following a staged pericardial fenestrated Fontan procedure. Transoesophageal echocardiogram showed a wide fenestration of 9 mm in size with a severely dilated pericardial Fontan system. To avoid a new surgical procedure and as part of a compassionate use programme, we decided to implant an atrial flow regulator device (4 mm in diameter) with percutaneous approach with the goal of reducing the right-to-left shunt and increasing the pulmonary flow. Preprocedural oxygen saturation was 75%, whereas after 2 months of follow-up, we observed a progressive increase of up to 95% with significant reduction in the pericardial Fontan system dimensions at echocardiography.
No takes yet. Share an insight, caveat, or question.
Manuri et al. (2018) conducted a case report in Complex congenital heart disease with severe cyanosis following a staged pericardial fenestrated Fontan procedure (n=1). Atrial flow regulator device was evaluated on Oxygen saturation. Percutaneous implantation of a 4-mm atrial flow regulator device in a 4-year-old male with a failing Fontan circulation increased oxygen saturation from 75% to 95% at 2 months.