Slowly adapting pulmonary stretch receptors provide signals related to the work of breathing, with discharge frequency varying by lung volume and rate of change.
Answers are grounded in this paper and cite their sources.
Animal data on pulmonary stretch receptor dynamics warrant no practice change; leaves open human mechanistic validation.
Action potentials of single vagal afferent nerve fibers from slowly adapting pulmonary stretch receptors, transpulmonary pressure and rate of air flow were recorded in anesthetized cats with open thoraxes during varied volumes and rates of inflation and deflation of the lungs. Both discharge frequency and total transpulmonary pressure varied with lung volume and also with its rate and sign of change. Effects of acceleration of volume on discharge frequency were not observed. The receptors provide signals related to the work of breathing.
No takes yet. Share an insight, caveat, or question.
Davis et al. (1956) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: