Key result
Corrected carotid flow time measured by a portable handheld ultrasound device was presented as a practical and noninvasive method to assess fluid responsiveness.
Why the study?
Balancing intraoperative volume resuscitation is difficult, and existing invasive or noninvasive methods to assess fluid responsiveness are often impractical, technically challenging, costly, or require mechanical ventilation.
Does corrected carotid flow time (ccFT) measured by a portable handheld ultrasound device effectively assess fluid responsiveness in the perioperative period?
Case Report (n=1)
Does corrected carotid flow time (ccFT) measured by a portable handheld ultrasound device effectively assess fluid responsiveness in the perioperative period?
Corrected carotid flow time measured via handheld ultrasound may offer a practical, noninvasive method for assessing fluid responsiveness perioperatively without the need for invasive lines or costly sensors.
May support noninvasive perioperative fluid assessment; hypothesis-generating case report requiring prospective validation.
Volume resuscitation is a cornerstone of modern anesthesia care. Finding the right balance to avoid inadequate or excess volume administration is often difficult to clinically discern and can lead to negative consequences. Pulse pressure variation is often intraoperatively used to guide volume resuscitation; however, this requires an invasive arterial line and is generally only applicable to patients who are mechanically ventilated. Unfortunately, without a pulmonary artery catheter or another costly noninvasive device, performing serial measurements of cardiac output is challenging, time-consuming, and often impractical. Furthermore, noninvasive measures such as LVOT VTI require significant technical expertise as well as access to the chest, which may not be practical during and after surgery. Other noninvasive techniques such as bioreactance and esophageal Doppler require the use of costly single-use sensors. Here, we present a case report on the use of corrected carotid flow time (ccFT) from a portable, handheld ultrasound device as a practical, noninvasive, and technically straightforward method to assess fluid responsiveness in the perioperative period, as well as the inpatient and outpatient settings.
No takes yet. Share an insight, caveat, or question.
Gibson et al. (2023) conducted a case report in Fluid responsiveness (n=1). Corrected carotid flow time (ccFT) via portable handheld ultrasound was evaluated. Corrected carotid flow time measured by a portable handheld ultrasound device was presented as a practical and noninvasive method to assess fluid responsiveness.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: