Key result
Carotid corrected flow time reliably predicts fluid responsiveness during low tidal volume ventilation, outperforming PPV.
Why the study?
Predicting fluid responsiveness in patients under mechanical ventilation with low tidal volume is challenging.
Does carotid corrected flow time predict fluid responsiveness better than pulse pressure variation in postoperative patients mechanically ventilated with low tidal volume?
Observational (n=36)
No
Does carotid corrected flow time predict fluid responsiveness better than pulse pressure variation in postoperative patients mechanically ventilated with low tidal volume?
Carotid corrected flow time assessed by ultrasound is a highly accurate predictor of fluid responsiveness during low tidal volume ventilation, outperforming pulse pressure variation.
Answers are grounded in this paper and cite their sources.
May support carotid corrected flow time over pulse pressure variation for fluid responsiveness assessment in low-tidal-volume ventilation; leaves open prospective validation before practice change.
Predicting fluid responsiveness in patients under mechanical ventilation with low tidal volume (VT) is challenging. This study evaluated the ability of carotid corrected flow time (FTc) assessed by ultrasound for predicting the fluid responsiveness during low VT ventilation. Patients under postoperative mechanical ventilation and clinically diagnosed with hypovolemia were enrolled. Carotid FTc and pulse pressure variation (PPV) were measured at VT of 6 and 10 mL/kg predicted body weight (PBW). FTc was calculated using both Bazett’s (FTcB) and Wodey’s (FTcW) formulas. Fluid responsiveness was defined as a ≥15% increase in the stroke volume index assessed by FloTrac/Vigileo monitor after administration of 8 mL/kg of balanced crystalloid. Among 36 patients, 16 (44.4%) were fluid responders. The areas under the receiver operating characteristic curves (AUROCs) for the FTcB at VT of 6 and 10 mL/kg PBW were 0.897 (95% confidence interval [95% CI]: 0.750–0.973) and 0.895 (95% CI: 0.748–0.972), respectively. The AUROCs for the FTcW at VT of 6 and 10 mL/kg PBW were 0.875 (95% CI: 0.722–0.961) and 0.891 (95% CI: 0.744–0.970), respectively. However, PPV at VT of 6 mL/kg PBW (AUROC: 0.714, 95% CI: 0.539–0.852) showed significantly lower accuracy than that of PPV at VT of 10 mL/kg PBW (AUROC: 0.867, 95% CI: 0.712–0.957; p = 0.034). Carotid FTc can predict fluid responsiveness better than PPV during low VT ventilation. However, further studies using automated continuous monitoring system are needed before its clinical use.
No takes yet. Share an insight, caveat, or question.
Jung et al. (2021) conducted an observational in Hypovolemia in mechanically ventilated patients (n=36). Carotid corrected flow time (FTc) by ultrasound vs. Pulse pressure variation (PPV) was evaluated on Prediction of fluid responsiveness (≥15% increase in stroke volume index) during low tidal volume (6 mL/kg PBW) mechanical ventilation (AUROC 0.897, 95% CI 0.750-0.973, p=<0.0001). Carotid corrected flow time accurately predicted fluid responsiveness during low tidal volume mechanical ventilation, demonstrating better predictive capability than pulse pressure variation.
Synapse has enriched 10 related papers. Consider them for comparative context: