Key result
Carotid corrected flow time reliably predicted fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery with an AUC of 0.82.
Why the study?
The ability of ultrasound-assessed carotid corrected flow time to predict fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position required evaluation.
Does carotid corrected flow time and tidal volume challenge predict fluid responsiveness in patients undergoing robot-assisted laparoscopic surgery?
Observational (n=52)
No
Does carotid corrected flow time and tidal volume challenge predict fluid responsiveness in patients undergoing robot-assisted laparoscopic surgery?
Carotid corrected flow time and the change in pulse pressure variation after a tidal volume challenge reliably predict fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery.
Answers are grounded in this paper and cite their sources.
May support fluid responsiveness assessment in robot-assisted gynecological surgery; hypothesis-generating and requires prospective validation before practice change.
Purpose We aimed to evaluate the ability of carotid corrected flow time assessed by ultrasound to predict fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. Methods This prospective single-center study conducted at the Chongqing University Cancer Hospital included patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position. Carotid doppler parameters and hemodynamic data, including corrected flow time, pulse pressure variation (PPV), stroke volume variation, and stroke volume index at a tidal volume of 6 mL/kg predicted body weight and after increasing the tidal volume to 8 mL/kg predicted body weight (tidal volume challenge), respectively, were measured. Fluid responsiveness was defined as a stroke volume index ≥10% increase after volume expansion. Results Among the 52 patients included, 26 were classified as fluid responders and 26 as non-responders based on the stroke volume index. The area under the receiver operating characteristic curve values measured to predict the fluid responsiveness to corrected flow time and changes in PPV (ΔPPV 6–8 ) after tidal volume challenge were 0.82 [95% confidence interval (CI): 0.705–0.937; P < 0.0001] and 0.85 (95% CI: 0.740–0.956; P < 0.0001), respectively. Both values were higher than those for PPV at a tidal volume of 8 mL/kg (0.79, 95% CI: 0.674–0.911; P = 0003). The optimal cut-off values for corrected flow time and ΔPPV 6–8 were 356.5 ms and >1%, respectively. Conclusion The change in PPV after tidal volume challenge and corrected flow time reliably predicted fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery in the modified head-down lithotomy position. Trial registration Chinese Clinical Trial Register (CHiCTR2200060573)
No takes yet. Share an insight, caveat, or question.
Tang et al. (2023) conducted an observational in Fluid responsiveness during surgery (n=52). Carotid corrected flow time (FTc) was evaluated on Prediction of fluid responsiveness (defined as stroke volume index ≥10% increase after volume expansion) (AUC 0.82, 95% CI 0.705-0.937, p=<0.0001). Carotid corrected flow time reliably predicted fluid responsiveness in patients undergoing robot-assisted laparoscopic gynecological surgery with an AUC of 0.82.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: