Why the study?
Does pulse pressure variation correlate with carotid artery corrected flow time in mechanically ventilated blunt trauma patients undergoing emergency laparotomy?
Does pulse pressure variation correlate with carotid artery corrected flow time in mechanically ventilated blunt trauma patients undergoing emergency laparotomy?
In a small retrospective study of blunt trauma patients undergoing emergency laparotomy, pulse pressure variation did not correlate with carotid artery corrected flow time.
Answers are grounded in this paper and cite their sources.
May support cautious carotid cFT use for fluid assessment in spontaneous breathers; leaves open prospective validation before adoption.
Dear Editor, Predictors of “fluid responsiveness” have been evaluated in clinical medicine to identify patients who require intravenous volume expansion and who require inotrope and/or vasopressors. Carotid artery corrected flow time (cFT) and respirophasic variation in carotid artery peak blood flow velocity (ðVpeak) have been used to predict fluid responsiveness in spontaneously breathing patients.[1,2] Carotid cFT increases with intravascular volume loading and can be used as a predictor of volume responsiveness. Carotid artery Doppler is noninvasive, technically easy to obtain measurements, and not affected by respiratory effort. In contrast, pulse pressure variation (PPV) is a validated measurement of volume responsiveness both in the perioperative period and in the intensive care unit in mechanically ventilated patients. In this retrospective analysis, hemodynamic data of blunt trauma patients undergoing emergency laparotomy after initial resuscitation was analyzed. Permission to conduct this study was obtained from the institute’s ethics committee (vide reference letter no IEC- 130/05.04.2019). After induction of general anesthesia, hemodynamic variables [heart rate, systolic blood pressure, diastolic blood pressure, mean arterial pressure, arterial oxygen saturation, cardiac rhythm, central venous pressure, PPV, and systolic pressure variation (SPV)] and USG-derived carotid artery flow time and carotid artery cycle time data were collected.[2] Data of 15 patients were analyzed in this study. The Median (IQR) time to surgery from injury was 8 (6–13) h, and the majority of patients were male (13 of 15 patients). All patients were mechanically ventilated with 6–8 mL/kg of tidal volume and PEEP of 5–6 cm H2O. The median (IQR) CVP was 9 (6–11) cm H2O. No statistical correlation was found between PPV and carotid artery cFT (r2= −0.002, P = 0.99, Spearman’s rank correlation; Figure 1). Similarly, no correlation was found between SPV and carotid artery cFT (r2= −0.01, P = 0.95, Spearman’s rank correlation; Figure 1). However, PPV and SPV were significantly correlated (r2 = 0.93, P < 0.001, Spearman’s rank correlation). There was no statistical correlation with CVP and carotid artery cFT, PPV, and SPV [Figure 2]. Visual inspection of the scatterplots indicates the possibility of nonlinear association.Figure 1: Scatter plot showing the correlation between carotid artery cFT, PPV, and SPVFigure 2: Scatter plot showing the correlation between CVP, carotid artery cFT, and PPVThough PPV is used as a marker of volume responsiveness,[3] it delineates the position of the heart in the Frank–Sterling curve. A high PPV indicates that the heart is in the steep portion of the curve; thus, a preload augmentation increases cardiac output[4] and a PPV of >13% reliably predicts fluid responsiveness. Acute hemorrhage causes activation of the sympathoadrenal system, leading to increased myocardial contractility and afterload. In contrast, volume resuscitation may cause an increase in preload and possibly a decrease in systemic vascular resistance (SVR). Induction of general anesthesia and use of volatile anesthetic agents also cause a decrease in SVR. A reduced afterload might be the reason for higher carotid artery cFT in these patients. Previous studies indicate that aortic cFT is inversely related to afterload and minimally affected by myocardial contractility.[4,5] We observed that PPV and carotid artery cFT are not statistically correlated in blunt trauma patients undergoing emergency laparotomy. The possibility of nonlinear association needs to be explored in a larger study. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Maitra et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: