Key result
Carotid-corrected flow time predicts fluid responsiveness better than FTc changes, with an AUC of ~0.82.
Why the study?
The ability of carotid-corrected flow time and changes in FTc induced by volume expansion to predict fluid responsiveness in robot-assisted gynecological surgery patients was unclear.
Does carotid-corrected flow time (FTc) predict fluid responsiveness in patients undergoing robot-assisted gynecological surgery?
Observational (n=52)
Does carotid-corrected flow time (FTc) predict fluid responsiveness in patients undergoing robot-assisted gynecological surgery?
Effect estimate: AUC 0.82 (95% CI 0.705-0.937)
p-value: p=<0.0001
Carotid-corrected flow time (FTc) is a reliable predictor of fluid responsiveness in patients undergoing robot-assisted gynecological surgery in a modified head-down lithotomy position.
Carotid FTc may predict fluid responsiveness in this setting; leaves open need for randomized validation before clinical adoption.
This prospective study aimed to evaluate the ability of point-of-care Doppler ultrasound measurements of carotid-corrected flow time and changes in corrected carotid flow time (FTc) induced by volume expansion to predict fluid responsiveness in patients undergoing robot-assisted gynecological surgery in a modified head-down lithotomy position. FTc was measured using Doppler images of the common carotid artery before and after volume expansion. The stroke volume index at each time point was recorded using the MostCare instrument. Fluid responsiveness was defined as a stroke volume index ≥10% increase after volume expansion. Half (50%) of the 52 patients responded positively. The areas under the receiver operating characteristic curves measured to predict fluid responsiveness for the corrected carotid flow time and changes in the FTc were 0.82 [95% confidence interval:0.705–0.937; P < 0.0001] and 0.67 (95% confidence interval:0.520–0.815; P < 0.05), respectively. The optimal cut-off value for the FTc and the change in FTc were 356.5 ms and 19.5 ms, respectively. FTc is a more reliable predictor of fluid responsiveness than FTc induced by volume expansion in gynecological patients undergoing robot-assisted laparoscopic surgery in the modified head-down lithotomy position.
No takes yet. Share an insight, caveat, or question.
Tang et al. (2023) conducted an observational in Robot-assisted gynecological surgery (n=52). Carotid-corrected flow time (FTc) vs. Changes in FTc induced by volume expansion was evaluated on Fluid responsiveness (stroke volume index ≥10% increase after volume expansion) (AUC 0.82, 95% CI 0.705-0.937, p=<0.0001). Carotid-corrected flow time (AUC 0.82; 95% CI 0.705-0.937) is a more reliable predictor of fluid responsiveness than changes in FTc (AUC 0.67) during robot-assisted gynecological surgery.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: