Key result
Severance of the chordae tendineae after mitral valve replacement in dogs considerably reduced systolic shortening of the major axis diameter by 20-27% at any left-ventricular end-diastolic pressure.
Why the study?
Does severance of the chordae tendineae alter left-ventricular dimensions and systolic function in a canine model of mitral valve replacement?
Does severance of the chordae tendineae alter left-ventricular dimensions and systolic function in a canine model of mitral valve replacement?
In a canine model, severance of the subvalvular apparatus during mitral valve replacement significantly alters left ventricular geometry and impairs systolic shortening of the major axis.
Answers are grounded in this paper and cite their sources.
Chordal preservation may help maintain LV shortening after mitral valve replacement; leaves open translation from canine models to patients.
To study the significance of the subvalvular apparatus for left-ventricular performance in mitral valve replacement, a new experimental model was developed. In 21 dogs St. Jude prostheses were implanted in the mitral position preserving the chordae tendineae and the papillary muscles by plicating and fixing the mitral leaflets with the prosthesis on the valvular annulus. Flexible steel wires were slung around the chordae tendineae of the anterior and the posterior papillary muscle separately and passed through the left ventricular wall via insulating plastic cannulas. Left-ventricular dimensions and global systolic function were measured during volume loading with blood before and after severance of the chordae tendineae by external application of electrocautery to the steel wires. Thus the heart continued beating without any interference following loss of the subvalvular apparatus. The external left ventricular diameters in the major and minor axis were determined by sonomicrometry. Left-ventricular systolic and diastolic pressures were measured by catheter tip manometers, stroke volume by electromagnetic measurements of flow in the ascending aorta. When the chordae tendineae had been cut, left-ventricular end-diastolic diameters in the major axis were increased ( + 2%), in the minor axis decreased (-1%) at any left-ventricular end-diastolic pressure. Systolic shortening of the major axis diameter was considerably reduced (20-27%) at any left-ventricular end-diastolic pressure following severance of the chordae tendineae. Significant increase of the systolic shortening in the minor axis diameter occurred at preload levels of 3-6 mmHg (15-8%), while at higher left-ventricular end-diastolic pressure of 7-8 mmHg no significant changes were present.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Gams et al. (1991) studied Mitral valve replacement (experimental model) (n=21). Severance of the chordae tendineae vs. Before severance of the chordae tendineae (intact subvalvular apparatus) was evaluated on Systolic shortening of the major axis diameter. Severance of the chordae tendineae after mitral valve replacement in dogs considerably reduced systolic shortening of the major axis diameter by 20-27% at any left-ventricular end-diastolic pressure.