Key result
The addition of adenosine stress perfusion-CMR to LGE-CMR altered the diagnosis of heart failure etiology in only 2 of 100 patients with severe LVSD, demonstrating excellent agreement.
Why the study?
Does the addition of adenosine stress perfusion imaging to LGE-CMR improve diagnostic accuracy for establishing the etiology of heart failure in patients with severe LVSD?
Observational (n=100)
Blinded image analysis
No
Does the addition of adenosine stress perfusion imaging to LGE-CMR improve diagnostic accuracy for establishing the etiology of heart failure in patients with severe LVSD?
The addition of adenosine stress perfusion imaging to standard LGE-CMR provides minimal incremental diagnostic yield for determining the etiology of heart failure in patients with severe LVSD.
Answers are grounded in this paper and cite their sources.
Minimal yield supports against routine stress perfusion-CMR addition; leaves open prospective outcome trials in severe LVSD.
BACKGROUND: Late gadolinium enhanced cardiovascular magnetic resonance (LGE-CMR) has excellent specificity, sensitivity and diagnostic accuracy for differentiating between ischemic cardiomyopathy (ICM) and non-ischemic dilated cardiomyopathy (NICM). CMR first-pass myocardial perfusion imaging (perfusion-CMR) may also play role in distinguishing heart failure of ischemic and non-ischemic origins, although the utility of additional of stress perfusion imaging in such patients is unclear. The aim of this retrospective study was to assess whether the addition of adenosine stress perfusion imaging to LGE-CMR is of incremental value for differentiating ICM and NICM in patients with severe left ventricular systolic dysfunction (LVSD) of uncertain etiology. METHODS: We retrospectively identified 100 consecutive adult patients (median age 69 years (IQR 59-73)) with severe LVSD (mean LV EF 26.6 ± 7.0%) referred for perfusion-CMR to establish the underlying etiology of heart failure. The cause of heart failure was first determined on examination of CMR cine and LGE images in isolation. Subsequent examination of complete adenosine stress perfusion-CMR studies (cine, LGE and perfusion images) was performed to identify whether this altered the initial diagnosis. RESULTS: On LGE-CMR, 38 patients were diagnosed with ICM, 46 with NICM and 16 with dual pathology. With perfusion-CMR, there were 39 ICM, 44 NICM and 17 dual pathology diagnoses. There was excellent agreement in diagnoses between LGE-CMR and perfusion-CMR (κ 0.968, p<0.001). The addition of adenosine stress perfusion images to LGE-CMR altered the diagnosis in only two of the 100 patients. CONCLUSION: The addition of adenosine stress perfusion-CMR to cine and LGE-CMR provides minimal incremental diagnostic yield for determining the etiology of heart failure in patients with severe LVSD.
No takes yet. Share an insight, caveat, or question.
Gulsin et al. (2017) conducted an observational in Severe left ventricular systolic dysfunction (LVSD) (n=100). Adenosine stress perfusion-CMR vs. LGE-CMR alone was evaluated on Agreement in diagnosis of heart failure etiology between LGE-CMR and perfusion-CMR (κ 0.968, p=<0.001). The addition of adenosine stress perfusion-CMR to LGE-CMR altered the diagnosis of heart failure etiology in only 2 of 100 patients with severe LVSD, demonstrating excellent agreement.
Synapse has enriched 10 related papers. Consider them for comparative context: