Answers are grounded in this paper and cite their sources.
Whole liver grafts harvested from 28 donors between February 2016 and June 2021 benefitted from HOPE: 9 otherwise discarded grafts were assessed and considered not fit for transplantation, while the other 19 were ECD or standard grafts that were subsequently transplanted. Dual HOPE was used in 8 out of the 19 procedures (42.1%). We obtained a significant increase of arterial and portal flow (p=0.005 and p=0.001, respectively). In recipients, significant improvement of AST, ALT, INR and lactate values were recorded (p 0.001, p 0.001, p 0.001, and p=0.05, respectively). The rate of major postoperative complications (Dindo-Clavien grade 3) after LT was 26.3%, while the rate of early graft dysfunction was 15.8%. No PRS or acute rejection was recorded. The postoperative mortality rate was 15.8%. After a median follow-up of 9.3 months (range 2-44), the late major complication rate was 15.8%, without mortality. Conclusion: Machine perfusion is nowadays part of current clinical practice. This way, marginal liver grafts (DCD, ECD-DBD) may be safely used for transplantation improving the outcome, thus effectively enhance the use of a persistent scarce pool of donors. For best results, we believe that both techniques of HOPE (mono and dual HOPE) should be used based on specific selection criteria.
No takes yet. Share an insight, caveat, or question.
Nicolaescu et al. (2021) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: