Key result
One-segment tissue Doppler detects ~3-point lower peak systolic strain in asphyxiated neonates with superior reproducibility.
Why the study?
Does one-segment tissue Doppler strain and strain rate analysis improve measurement repeatability compared with two-segment analysis and detect reduced myocardial performance in asphyxiated term neonates compared with healthy term neonates?
Cohort (n=68)
No
Does one-segment tissue Doppler strain and strain rate analysis improve measurement repeatability compared with two-segment analysis and detect reduced myocardial performance in asphyxiated term neonates compared with healthy term neonates?
One-segment tissue Doppler strain and strain rate analysis provides a fast, significantly more reproducible method than two-segment analysis for detecting impaired systolic and diastolic myocardial performance in term neonates with perinatal asphyxia, even when conventional fractional shortening appears normal.
Answers are grounded in this paper and cite their sources.
One-segment tissue Doppler may aid repeatable myocardial assessment in asphyxiated neonates; leaves open its prognostic value and clinical utility.
OBJECTIVES: To investigate one-segment strain and strain rate indices as measures of myocardial performance in asphyxiated term neonates. DESIGN: Quality improvement cohort study. SETTING: Newborns admitted to a neonatal intensive care unit at a Norwegian University Hospital for perinatal asphyxia and non-asphyxiated newborn recruited from the maternity ward at the same hospital. PARTICIPANTS: Twenty asphyxiated and 48 non-asphyxiated term neonates. PRIMARY OUTCOME MEASURE: Strain and strain rate indices and repeatability measures. One-segment longitudinal strain and strain rate by tissue Doppler were assessed on days 1, 2 and 3 of life in nine heart walls. Repeatability was compared against measurements from two-segment analyses previously performed in the same images. RESULTS: The 95% limits of agreement were significantly better for the one-segment than two-segment repeatability analyses, the inter-rater peak systolic strain (PSS) was (-3.1, 3.3) vs (-11.4, 18.3)%, the inter-rater peak systolic strain rate (PSSR) was (-0.38, 0.40) vs (-0.79, 1.15)/s, the intra-rater PSS was (-2.5, 2.6) vs (-8.0, 9.8)% and the intra-rater PSSR was (-0.23, 0.25) vs (-0.75, 0.80)/s (p<0.05). The myocardial performance was lower in the asphyxiated neonates (indices closer to zero) than in the non-asphyxiated neonates, PSS was -17.8 (0.6) (mean (SEM)) vs -21.2 (0.3)%, PSSR -1.43 (0.08) vs -1.61 (0.03)/s, early diastolic strain rate 1.72 (0.11) vs 2.00 (0.11)/s and strain rate during the atrial systole 1.92 (0.17) vs 2.27 (0.10)/s (p<0.05), despite no difference in fractional shortening (29.0 (0.5) vs 29.1 (1.0)%) (p>0.05). CONCLUSIONS: One-segment strain and strain rate assessed the reduced myocardial performance in asphyxiated neonates with significantly improved reproducibility as compared with two-segment analysis and was therefore more feasible than two-segment analyses for assessment of myocardial performance after perinatal asphyxia.
No takes yet. Share an insight, caveat, or question.
Nestaas et al. (2012) conducted a cohort in Perinatal asphyxia in term neonates (n=68). One-segment longitudinal strain and strain rate analysis by tissue Doppler echocardiography (and exposure to perinatal asphyxia) vs. Non-asphyxiated term neonates (and two-segment strain/strain rate analysis for repeatability) was evaluated on One-segment peak systolic strain (PSS) across all nine myocardial walls (p=<0.001). One-segment tissue Doppler analysis detected reduced peak systolic strain in asphyxiated vs healthy neonates with superior inter-rater limits of agreement.