Key result
Indirect fluorescent antibody tests and ELISAs demonstrated fair to almost perfect agreement and high accuracy (AUC 0.72-1.00) for detecting PCV-2 antibodies across 7 laboratories.
Serologic tests for PCV-2 antibodies show high diagnostic accuracy, though test sensitivities vary based on laboratory-specific cutoffs.
Answers are grounded in this paper and cite their sources.
Supports interlaboratory standardization of PCV-2 serology; leaves open optimal cutoff validation in field conditions.
A blinded interlaboratory assessment of the diagnostic agreement and accuracy of serologic tests for routine detection of antibodies against Porcine circovirus-2 (PCV-2), including indirect fluorescent antibody tests (IFATs) and enzyme-linked immunosorbent assays (ELISAs) was conducted in 7 North American laboratories. Serum samples were collected weekly, on trial days 0, 7, 14, 21, 28, 35, 42, and 49, from the following groups of animals: 1) negative controls (n = 7), 2) PCV-2a (n = 8), 3) PCV-2b (n = 8), 4) PCV-1 (n = 8), 5) PCV-2 vaccine A (n = 8; Ingelvac® CircoFLEX™), 6) PCV-2 vaccine B (n = 8; Circumvent® PCV2), and 7) PCV-2 vaccine C (n = 8; Suvaxyn® PCV2 One Dose). Results from each laboratory were analyzed by kappa and receiver operating characteristic (ROC) analysis. Kappa analysis indicated that, by trial day 49, IFATs had almost perfect agreement, in-house ELISAs had fair to almost perfect agreement, and commercially available anti-PCV-2 immunoglobulin G ELISAs (I or S) had moderate to substantial agreement. From trial days 14-49, the area under the ROC curve for the 2 laboratories that offered IFATs, the 4 laboratories that offered in-house ELISAs, and the 3 laboratories that used commercially available ELISAs ranged from 0.94 to 1.00, 0.72 to 1.00, and 0.95 to 1.00, respectively. However, test sensitivities varied based on laboratory-specific cutoffs that were used to dichotomize test results.
No takes yet. Share an insight, caveat, or question.
Patterson et al. (2011) studied Porcine circovirus-2 (PCV-2) infection (n=55). Indirect fluorescent antibody tests (IFATs) and enzyme-linked immunosorbent assays (ELISAs) was evaluated on Diagnostic agreement (kappa) and accuracy (area under the ROC curve). Indirect fluorescent antibody tests and ELISAs demonstrated fair to almost perfect agreement and high accuracy (AUC 0.72-1.00) for detecting PCV-2 antibodies across 7 laboratories.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: