Key result
Impedance cardiography showed good agreement and a significant correlation with Doppler echocardiography for measuring preload reserve in pregnant women.
Why the study?
Does impedance cardiography agree with Doppler echocardiography in measuring preload reserve in healthy pregnant women?
Cross-Sectional (n=53)
No
Does impedance cardiography agree with Doppler echocardiography in measuring preload reserve in healthy pregnant women?
Impedance cardiography shows good agreement with Doppler echocardiography for noninvasive assessment of preload reserve in pregnant women.
Answers are grounded in this paper and cite their sources.
May support noninvasive ICG monitoring in pregnancy; leaves open need for outcome validation before clinical use.
PURPOSE: Accurate assessment of cardiac function is important during pregnancy. Echocardiography and impedance cardiography (ICG) are commonly used noninvasive methods to measure stroke volume (SV) and cardiac output (CO). The difference in stroke volume (ΔSV) or cardiac output (ΔCO) measured at baseline and after passive leg raising (PLR) is a measure of preload reserve that predicts volume responsiveness. However, the agreement between these two methods in measuring preload reserve during pregnancy is unclear. The aim of our study was to investigate the correlation and the agreement between Doppler echocardiography and ICG in assessing preload reserve in pregnant women. METHODS: In this prospective observational cross-sectional study, preload reserve was assessed by measuring the SV and CO during baseline and 90 s after PLR simultaneously by Doppler echocardiography and ICG in healthy pregnant women during the second and third trimesters. Bland-Altman analysis was used to determine the agreement between the two methods. Bias was calculated as the mean difference between two methods and precision as 1.96 SD of the difference. RESULTS: A total of 53 pregnant women were included. We found a statistically significant correlation between ΔSV (R = 0.56, p < 0.0001) and ΔCO (R = 0.39, p = 0.004) measured by ICG and Doppler echocardiography. The mean bias for ΔSV was 2.52 ml, with a precision of 18.19 ml. The mean bias for ΔCO was 0.21 l/min, with a precision of 1.51 l/min. CONCLUSION: There was a good agreement and a statistically significant correlation between ICG and Doppler echocardiography for measuring preload reserve.
No takes yet. Share an insight, caveat, or question.
Liang et al. (2018) conducted a cross-sectional in Healthy pregnancy (n=53). Impedance cardiography vs. Doppler echocardiography was evaluated on Agreement and correlation between change in stroke volume (ΔSV) and cardiac output (ΔCO) measured by ICG and Doppler echocardiography (R = 0.56 for ΔSV; mean bias 2.52 ml, p=<0.0001). Impedance cardiography showed good agreement and a significant correlation with Doppler echocardiography for measuring preload reserve in pregnant women.
Synapse has enriched 10 related papers. Consider them for comparative context: