Key result
Retained wire femoral lead removal and fibroplasty successfully achieved venous access in 100% (17/17) of patients with refractory venous obstruction, with no procedure-related complications.
Why the study?
Pectoral transvenous lead extraction for refractory venous occlusion carries major complication risks and can damage nontargeted leads, prompting evaluation of retained wire femoral lead removal and fibroplasty.
Does retained wire femoral lead removal and fibroplasty safely achieve venous access in patients with refractory venous obstruction?
Observational (n=17)
Does retained wire femoral lead removal and fibroplasty safely achieve venous access in patients with refractory venous obstruction?
Retained wire femoral lead removal and fibroplasty is a safe and effective technique for obtaining venous access in patients with refractory venous occlusion, potentially avoiding the risks associated with transvenous lead extraction.
Answers are grounded in this paper and cite their sources.
Femoral fibroplasty may restore venous access without TLE; hypothesis-generating in Level 4 data.
BACKGROUND: Patients with wire and catheter refractory venous occlusion are traditionally referred for pectoral transvenous lead extraction (TLE) to obtain venous access. TLE causes 1-2 mm circumferential mechanical or laser destruction of tissue surrounding the lead(s). This not only exposes the patient to the risk of major complications but also can damage nontargeted leads. We present a series of patients where retained wire femoral lead removal and fibroplasty was used to obtain venous access in patients with refractory obstruction. METHODS: Between 2008 and 2021, we identified 17 patients where retained wire lead removal followed by fibroplasty was used to retain venous access. Demographic and procedural data were obtained by retrospective review of patient charts. RESULTS: We were able to successfully obtain venous access in all 17 patients in whom this technique was attempted. In two patients the target lead was less than or equal to 1 year old. In the remaining 15 patients, the average dwell time of the target lead(s) was 6 years. There were no procedure-related complications, and no changes in the parameters of other leads were noted. CONCLUSION: Retained wire femoral lead removal and fibroplasty is safe and highly efficacious at obtaining venous access in patients with refractory venous occlusion. If the target lead(s) is less than or equal to 1 year old, this technique can help obtain venous access at the time of the initial surgery, hence avoiding the need for TLE. Furthermore, in patients referred for TLE to obtain venous access, this technique by avoiding the use of TLE tools spares the patient of the associated risks.
No takes yet. Share an insight, caveat, or question.
Brar et al. (2021) conducted an observational in Refractory venous obstruction (n=17). Retained wire femoral lead removal and fibroplasty was evaluated on Successful venous access. Retained wire femoral lead removal and fibroplasty successfully achieved venous access in 100% (17/17) of patients with refractory venous obstruction, with no procedure-related complications.