Key result
Although there was significant variance in absolute velocity measurements among 15 vascular scientists, no single operator consistently produced highly variable results.
Cross-Sectional (n=15)
Double-blind
Yes
Despite significant variance in absolute velocity measurements likely due to biological variability, vascular scientists were generally consistent in obtaining optimal spectral Doppler traces, highlighting the challenges of standardizing carotid ultrasound measurements.
Answers are grounded in this paper and cite their sources.
Operator variability in carotid velocities warrants caution in serial clinical measurements; leaves open need for standardized protocols in research.
Introduction Duplex ultrasound is often the sole imaging modality used in diagnosing carotid artery disease. However, the reproducibility and repeatability of scientists in determining the peak systolic velocity and end diastolic velocity of the internal carotid artery and common carotid artery (CCA) is widely debated. Study aim To investigate intra- and inter-operator variability in diagnostic ultrasound of the carotid arteries across a centralised vascular network using a healthy test subject. To identify potential causes of variability and highlight areas for improvement. Methods Fifteen vascular scientists across four hospital Trusts in the Bristol, Bath and Weston vascular network measured the peak systolic velocity and end diastolic velocity of the internal carotid artery and common carotid artery in a subject using a single portable ultrasound machine. A double blind assessment of spectral Doppler images was performed by two vascular clinical scientists for optimal caliper placement, spectral gain and angle correction. Results were compared for intra- and inter-operator variability. Results Initial quality assessment of the Doppler images revealed that three out of 15 scientists produced suboptimal results. Box plot analysis of the common carotid artery and internal carotid artery for each scientist revealed significant variance (ANOVA p < 0.05). However, a Levene’s test revealed no single operator who consistently produced highly variable results ( p = 0.569). Conclusion This study highlights the difficulty in obtaining consistent velocity measurements from a subject. Despite the variability in absolute peak systolic velocity and end diastolic velocity, scientists were generally consistent in obtaining an optimal spectral Doppler trace. Some issues with consistency were, however, identified which were subsequently addressed.
No takes yet. Share an insight, caveat, or question.
McKenna et al. (2018) conducted a cross-sectional in Carotid artery disease (diagnostic variability) (n=15). Carotid artery duplex ultrasound measurement by different operators vs. Intra- and inter-operator comparisons was evaluated on Intra- and inter-operator variability in peak systolic velocity (PSV) and end diastolic velocity (EDV) (p=<0.05). Although there was significant variance in absolute velocity measurements among 15 vascular scientists, no single operator consistently produced highly variable results.
Synapse has enriched 10 related papers. Consider them for comparative context: