A relatively simple preparation and contacting procedure for Hall and conductivity measurements on semi-insulating GaAs at room temperature is described. The influence of some preparation and measuring conditions on the values of σ and RH is investigated: parameters of the equipment, temperature accuracy, contacts, preparation procedure, purity of the agents as well as the time between preparation and measurement. As criterion for the correct determination of σ and RH the thickness independence of these parameters is used. Errors due to unsufficient surface preparation cannot be excluded by measuring at elevated temperature (400 K).