Key result
Single-lead atrial pacing did not significantly differ from dual-chamber pacing in all-cause death (HR 1.06; 95% CI 0.88-1.29; P=0.53), but was associated with higher risks of AF and reoperation.
Why the study?
Does single-lead atrial pacing (AAIR) reduce death from any cause compared to dual-chamber pacing (DDDR) in patients with sick sinus syndrome?
RCT (n=1,415)
Does single-lead atrial pacing (AAIR) reduce death from any cause compared to dual-chamber pacing (DDDR) in patients with sick sinus syndrome?
In patients with sick sinus syndrome, single-lead atrial pacing offers no survival benefit over dual-chamber pacing and increases the risk of paroxysmal atrial fibrillation and pacemaker reoperation, supporting the routine use of DDDR pacing.
Answers are grounded in this paper and cite their sources.
Supports DDDR preference in sick sinus syndrome; reinforces consensus against AAIR for this indication.
AIMS: In patients with sick sinus syndrome, bradycardia can be treated with a single-lead pacemaker or a dual-chamber pacemaker. Previous trials have revealed that pacing modes preserving atrio-ventricular synchrony are superior to single-lead ventricular pacing, but it remains unclear if there is any difference between single-lead atrial pacing (AAIR) and dual-chamber pacing (DDDR). METHODS AND RESULTS: We randomly assigned 1415 patients referred for first pacemaker implantation to AAIR (n = 707) or DDDR (n = 708) pacing and followed them for a mean of 5.4 ± 2.6 years. The primary outcome was death from any cause. Secondary outcomes included paroxysmal and chronic atrial fibrillation, stroke, heart failure, and need for pacemaker reoperation. In the AAIR group, 209 patients (29.6%) died during follow-up vs. 193 patients (27.3%) in the DDDR group, hazard ratio (HR) 1.06, 95% confidence interval (CI) 0.88-1.29, P = 0.53. Paroxysmal atrial fibrillation was observed in 201 patients (28.4%) in the AAIR group vs. 163 patients (23.0%) in the DDDR group, HR 1.27, 95% CI 1.03-1.56, P = 0.024. A total of 240 patients underwent one or more pacemaker reoperations during follow-up, 156 (22.1%) in the AAIR group vs. 84 (11.9%) in the DDDR group (HR 1.99, 95% CI 1.53-2.59, P < 0.001). The incidence of chronic atrial fibrillation, stroke, and heart failure did not differ between treatment groups. CONCLUSION: In patients with sick sinus syndrome, there is no statistically significant difference in death from any cause between AAIR pacing and DDDR pacing. AAIR pacing is associated with a higher incidence of paroxysmal atrial fibrillation and a two-fold increased risk of pacemaker reoperation. These findings support the routine use of DDDR pacing in these patients. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT00236158.
No takes yet. Share an insight, caveat, or question.
Nielsen et al. (2011) conducted an RCT in sick sinus syndrome (n=1,415). Single-lead atrial pacing (AAIR) vs. Dual-chamber pacing (DDDR) was evaluated on death from any cause (HR 1.06, 95% CI 0.88-1.29, p=0.53). Single-lead atrial pacing did not significantly differ from dual-chamber pacing in all-cause death (HR 1.06; 95% CI 0.88-1.29; P=0.53), but was associated with higher risks of AF and reoperation.
Synapse has enriched 10 related papers. Consider them for comparative context: