Key result
AAIR pacing shows no difference in device sepsis or lead revision versus DDDR in SND.
Why the study?
The clinical outcomes of AAIR versus DDDR pacing in patients with sinus node dysfunction were compared to guide pacing choice based on AV nodal functional testing.
Does AAIR pacing improve clinical outcomes compared to DDDR pacing in patients with sinus node dysfunction?
Cohort
Does AAIR pacing improve clinical outcomes compared to DDDR pacing in patients with sinus node dysfunction?
In patients with sinus node dysfunction, AAIR pacing guided by AV nodal functional testing is a viable alternative to DDDR pacing with a low risk of AV block or lead revision, particularly useful in resource-limited settings.
Answers are grounded in this paper and cite their sources.
Supports AAIR pacing after AV nodal testing as DDDR alternative in resource-limited settings; leaves open need for randomized confirmation.
OBJECTIVES: The aim of the study was to compare the clinical outcomes [atrial fibrillation (AF), atrio-ventricular (AV) block, device sepsis and lead revision] of patients with sinus node dysfunction (SND) between atrial-pacing atrial-sensing inhibited-response rate-adaptive (AAIR) versus dual-chamber rate-adaptive (DDDR) pacing. The choice of AAIR pacing versus DDDR pacing was determined by AV nodal functional testing at implant. METHODS: We conducted a retrospective review of consecutive patients who underwent AAIR and DDDR pacing over a 10-year period. AV block occurred in one patient in the AAIR group, who required an upgrade to a DDDR pacemaker. There was no difference in device sepsis or need for lead revision between the two groups. CONCLUSIONS: We found that AV nodal functional testing with atrial pacing at the time of pacemaker implantation was a useful tool to help guide the implanter between AAIR or DDDR pacing. Patients who underwent AAIR pacing had a low risk of AF, AV block or lead revision. In resource-limited settings, AAIR pacing guided by AV nodal functional testing should be considered as an alternative to DDDR pacing.
No takes yet. Share an insight, caveat, or question.
A 2021 study conducted a cohort in Sinus node dysfunction (SND). AAIR pacing vs. DDDR pacing was evaluated on Clinical outcomes including atrial fibrillation (AF), atrio-ventricular (AV) block, device sepsis and lead revision (p=0.70). AAIR pacing showed no difference in device sepsis or need for lead revision compared to DDDR pacing in patients with sinus node dysfunction.