Key result
AAI pacing mode compared to DDD mode in sick sinus syndrome showed that relative myocardial performance index correlated significantly with relative AV interval (r = 0.67, P < 0.0001).
Why the study?
Does AAI pacing mode improve myocardial performance index compared to DDD pacing mode in patients with sick sinus syndrome?
Cross-Sectional (n=39)
Does AAI pacing mode improve myocardial performance index compared to DDD pacing mode in patients with sick sinus syndrome?
In patients with sick sinus syndrome, myocardial performance index can help identify those who may benefit from DDD pacing with an optimal AV interval despite moderately prolonged intrinsic AV conduction.
MPI may aid AV optimization in DDD pacing for SSS; leaves open AAI versus DDD superiority.
BACKGROUND: Although the AAI pacing mode has been shown to be electromechanically superior to the DDD pacing mode in sick sinus syndrome (SSS), there is evidence suggesting that during AAI pacing the presence of natural ventricular activation pattern is not enough for hemodynamic benefit to occur. Myocardial performance index (MPI) is a simply measurable Doppler-derived index of combined systolic and diastolic myocardial performance. The aim of this study was to investigate whether AAI pacing mode is electromechanically superior to the DDD mode in patients with SSS by using Doppler-derived MPI. METHODS: Thirty-nine SSS patients with dual-chamber pacing devices were evaluated by using Doppler echocardiography in AAI mode and DDD mode. The optimal atrioventricular (AV) interval in DDD mode was determined and atrial stimulus-R interval was measured in AAI mode. The ratio of the atrial stimulus-R interval to the optimal AV interval was defined as relative AV interval (rAVI) and the ratio of MPI in AAI mode to that in DDD mode was defined as relative MPI (rMPI). RESULTS: The rMPI was significantly correlated with atrial stimulus-R interval and rAVI (r = 0.57, P = 0.0002, and r = 0.67, P < 0.0001, respectively). A cutoff point of 1.73 for rAVI provided optimum sensitivity and specificity for rMPI >1 based on the receiver operator curves. CONCLUSIONS: Even though the intrinsic AV conduction is moderately prolonged, some SSS patients with dual-chamber pacing devices benefit from the ventricular pacing with optimal AV interval. MPI is useful to determine the optimal pacing mode in acute experiment.
No takes yet. Share an insight, caveat, or question.
Kato et al. (2005) conducted a cross-sectional in Sick sinus syndrome (n=39). AAI pacing mode vs. DDD pacing mode was evaluated on Correlation between relative myocardial performance index (rMPI) and relative AV interval (rAVI) (r = 0.67, p=< 0.0001). AAI pacing mode compared to DDD mode in sick sinus syndrome showed that relative myocardial performance index correlated significantly with relative AV interval (r = 0.67, P < 0.0001).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: