Key result
Ultrasonic quantitative flow measurement detected lower ipsilateral common carotid blood flow in patients with complete occlusion of the internal carotid artery.
Why the study?
Can ultrasonic quantitative flow measurement (UQFM) accurately assess absolute common carotid flow in patients with cerebrovascular disease?
Observational (n=84)
Can ultrasonic quantitative flow measurement (UQFM) accurately assess absolute common carotid flow in patients with cerebrovascular disease?
Ultrasonic quantitative flow measurement is a useful tool for screening occlusive cerebrovascular disease and understanding ischemia mechanisms in the presence of carotid lesions.
Answers are grounded in this paper and cite their sources.
Supports UQFM for occlusive disease screening; leaves open accuracy for absolute carotid flow quantification.
Eighty-four patients with cerebrovascular disease were studied by cerebral angiography and a prototype Doppler device, ultrasonic quantitative flow measurement (UQFM), that provides data from which absolute common carotid flow can be determined. The UQFM showed significantly lower flows in 23 patients who had complete occlusion of the internal carotid artery on the affected side (p less than 0.001). In 11 patients with occlusion of hte middle cerebral artery at its origin and in 5 with branch occlusions, the blood flow in the ipsilateral common carotid artery was also significantly lower (p less than 0.01). There was no significant difference between blood flow on the 2 sides in 9 patients with stenosis of middle cerebral artery and in 7 with stenosis of internal carotid artery. Due to the small number of patients no definite conclusion can be drawn. The UQFM is thought to be useful not only in screening for occlusive cerebrovascular disease but also to help understand better the mechanisms of ischemia in the presence of carotid lesions.
No takes yet. Share an insight, caveat, or question.
Mizukami et al. (1981) conducted an observational in Cerebrovascular disease (n=84). Ultrasonic quantitative flow measurement (UQFM) vs. Unaffected side was evaluated on Absolute common carotid flow (p=<0.001). Ultrasonic quantitative flow measurement detected lower ipsilateral common carotid blood flow in patients with complete occlusion of the internal carotid artery.
Synapse has enriched 10 related papers. Consider them for comparative context: