Key result
Ultrasonic flow volumetry with CVI-Q yielded acceptable data in 97% of common carotids and revealed that men have a 15% higher volume flow rate than women.
Why the study?
Is ultrasonic flow volumetry with CVI-Q a feasible and accurate method for assessing cerebral hemodynamics in vitro and in normal volunteers?
Observational
Is ultrasonic flow volumetry with CVI-Q a feasible and accurate method for assessing cerebral hemodynamics in vitro and in normal volunteers?
Answers are grounded in this paper and cite their sources.
Ultrasonic flow volumetry with CVI-Q is a feasible and accurate method for assessing cerebral hemodynamics, demonstrating significant gender and age differences in normal volunteers.
Noninvasive hemodynamic testing of the cerebral vessels has been limited to the use of flow velocity rather than potentially more powerful parameters such as volume flow rate. Color velocity imaging (CVI), a time-domain based color flow imaging method, offers potential for volume flow rate determination. This technique uses a color M-mode function for simultaneous determination of flow velocity and functional vessel diameter. As flow volume (m3 × s-1) is the product of flow velocity (m × s-1) and area (m2) where this velocity occurs, these data are integrated to determine the effective flow volume. Before applying this new technique on clinical patients we tested the system in an in vitro setting and on normal volunteers. (1) In vitro flow volume tests on a computer-controlled flow phantom proved to be accurate for all constant flow volumes in a range of 120-1,040 ml/min and pulsatile flow volumes from 70 to 360 ml/min. (2) A major concern before utilizing this technique in daily practice is the question of in vivo intra- and interoperator variability. We found the interoperator variability overall negligible. Intraoperator variability is acceptable when at least three samples are obtained per site. (3) In a pilot study we performed an age-, gender- and race-matched community nomogram trial. Technically acceptable data could be obtained from almost all common carotids (97%), 71% of all internal carotids and 53% of all vertebrals arteries. We found a significant (p < 0.0001) difference of volume flow rate depending on gender, with men having a 15 % higher flow volume. A less striking correlation (p < 0.001) was found for an inverse relationship of age and volume flow rate. All other tested parameters (blood pressure, heart rate, race, level of education, smoking, weight, body surface) proved to be insignificant. In summary, ultrasonic flow volumetry with CVI-Q is a feasible method, which promises to be an exciting tool in the assessment of cerebral hemodynamics. Future studies will focus on the impact of carotid stenosis on volume flow rate and on clinical disorders like dementia, cardiac insufficiency or migraine.
No takes yet. Share an insight, caveat, or question.
Eicke et al. (2007) conducted an observational in Normal volunteers. Ultrasonic quantitative flow volumetry (CVI-Q) was evaluated on Volume flow rate (p=< 0.0001). Ultrasonic flow volumetry with CVI-Q yielded acceptable data in 97% of common carotids and revealed that men have a 15% higher volume flow rate than women.
Synapse has enriched 10 related papers. Consider them for comparative context: