Key result
Shear wave elastography measurements of renal cortical stiffness demonstrated good inter-observer agreement (average ICC 0.843) in diabetic patients.
Why the study?
The reproducibility of shear wave elastography and traditional morphometric measurements for assessing renal cortical stiffness in conditions such as diabetic kidney disease remains challenging due to operator dependency and imaging limitations.
Does ultrasound shear wave elastography provide reproducible measurements of renal cortical stiffness and morphometry between observers in adult diabetic patients?
Cross-Sectional (n=30)
Blinded observers
No
Does ultrasound shear wave elastography provide reproducible measurements of renal cortical stiffness and morphometry between observers in adult diabetic patients?
Shear wave elastography provides reproducible measurements of renal cortical stiffness between observers in diabetic patients, suggesting its potential utility as a reliable imaging biomarker.
Supports shear wave elastography reproducibility for renal stiffness in diabetes; hypothesis-generating for clinical adoption pending prospective validation.
Shear wave elastography (SWE) is increasingly used in renal imaging to assess cortical stiffness, potentially reflecting tissue alterations in conditions such as diabetic kidney disease. However, the reproducibility of SWE and traditional morphometric measurements remains a challenge. This is primarily due to factors such as operator dependency, variations in patient positioning, differences in breathing patterns during scanning, and the inherent technical limitations of ultrasound imaging. This pilot study aimed to assess the inter-observer agreement in ultrasound-based measurements of renal cortical stiffness, cortical thickness, length, and width in diabetic patients. In this prospective study, 30 adult diabetic patients underwent renal ultrasound performed by two independent observers. Parameters measured included cortical stiffness (kPa), cortical thickness (cm), kidney length (cm), and width (cm). Intraclass correlation coefficients (ICC), Bland-Altman plots, and Pearson's correlation were used to evaluate inter-observer variability and bias. Cortical stiffness measurements demonstrated good inter-observer agreement (ICC = 0.824 for left kidney, 0.762 for right kidney). Morphometric measurements such as renal length and width showed excellent agreement (ICC > 0.9), although systematic and proportional biases were present. Cortical thickness exhibited poor agreement (ICC < 0.5), despite the absence of systematic bias. SWE has potential role in detecting early changes in renal tissue stiffness. Cortical stiffness shows reproducible between observers and can be considered reliable in diabetic patient. Morphometric parameters show high variability in certain aspects, particularly cortical thickness.
No takes yet. Share an insight, caveat, or question.
Fahad Almutairi (2025) conducted a cross-sectional in Type 2 diabetes mellitus (n=30). Shear wave elastography (SWE) vs. Second independent observer was evaluated on Inter-observer agreement of average renal cortical stiffness (ICC 0.843, 95% CI 0.67-0.925, p=<0.001). Shear wave elastography measurements of renal cortical stiffness demonstrated good inter-observer agreement (average ICC 0.843) in diabetic patients.