Key result
TEVAR using a novel dissection-specific stent-graft for chronic type B aortic dissection achieved 96% technical success with 0% 30-day stroke, spinal cord ischemia, or re-interventions.
Why the study?
Short and mid-term outcomes of a novel dissection-specific stent-graft designed for chronic type B aortic dissection to reduce distal stent-graft-induced new entry tears were unknown.
Does a novel dissection-specific stent-graft prevent distal stent-graft-induced new entry tears and improve outcomes in patients undergoing TEVAR for chronic type B aortic dissection?
Cohort (n=16)
No
Does a novel dissection-specific stent-graft prevent distal stent-graft-induced new entry tears and improve outcomes in patients undergoing TEVAR for chronic type B aortic dissection?
A novel dissection-specific stent-graft for TEVAR in chronic type B aortic dissection appears safe and feasible, with low rates of distal stent-graft-induced new entry tears and satisfactory aortic remodeling at mid-term follow-up.
Supports safety of novel dissection-specific stent-graft for chronic TBAD TEVAR; leaves open need for RCTs to confirm dSINE prevention.
BACKGROUND: The aim was to report short and mid-term outcomes of a novel, investigational, dissection-specific stent-graft (DSSG), specifically designed to address the features of chronic type B aortic dissection (CTBAD) and reduce the risk of distal stent-graft-induced new entry tears (dSINE). MATERIALS AND METHODS: A retrospective single center cohort study of all patients undergoing TEVAR with the DSSG for CTBAD from January 1, 2017 to January 31, 2020. The DSSG, which is a modified stent-graft based on the Cook Zenith Alpha Thoracic platform, has no proximal barbs, and a customized longer body length with substantial taper. The second and third distal Z-stents are sited internally to avoid any contact of the metal skeleton with the dissection membrane and have reduced radial force, while the most distal stent was removed creating a distal 30 mm unsupported Dacron graft. RESULTS: Sixteen patients (13 males, 3 females) with a median age of 66 years (range 31-79 years) underwent elective TEVAR of CTBAD using the DSSG. Six patients (38%) had an underlying connective tissue disorder. The median tapering was 10 mm (range 4 mm-21 mm) and median length 270 mm (range 210-380 mm). Technical success was achieved in all but one case (96%). One patient died within 30 days, due to retrograde type A dissection with cardiac tamponade. The 30-day rate of stroke, spinal cord ischemia, and re-interventions was 0%. After median imaging follow-up time of 17 months (range 1-31 months), one patient developed a dSINE 4 months after the index procedure. After median survival follow-up of 23 months (range 2-35 months), one late death occurred due to traumatic brain injury, while no aortic-related death occurred during follow-up. Complete false lumen (FL) thrombosis was achieved in 9 patients while the remaining 6 showed partial FL thrombosis. No instances of diameter increase at the level oftreated aortic segment were noted with serial measurements showing either stable (n = 7) or decreased (n = 8) maximal transverse diameter. CONCLUSIONS: Use of a novel DSSG with low radial force for TEVAR in the setting of CTBAD is safe and feasible. This early real-world experience shows promising mid-term effectiveness with low rates of dSINE or unplanned re-interventions and satisfactory aortic remodeling during follow-up. Longer follow-up is needed, however, before any firm conclusions can be drawn.
No takes yet. Share an insight, caveat, or question.
Burdess et al. (2021) conducted a cohort in chronic type B aortic dissection (CTBAD) (n=16). dissection-specific stent-graft (DSSG) was evaluated on Technical success. TEVAR using a novel dissection-specific stent-graft for chronic type B aortic dissection achieved 96% technical success with 0% 30-day stroke, spinal cord ischemia, or re-interventions.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: