Key result
A novel multiplex real-time RT-PCR assay demonstrated 100% sensitivity and specificity for enterovirus and 91% sensitivity and 91.7% specificity for human parechovirus in clinical fecal samples.
Why the study?
What is the diagnostic accuracy of a novel multiplex one-step real-time RT-PCR assay for detecting enterovirus and parechovirus in fecal samples?
Cross-Sectional (n=111)
What is the diagnostic accuracy of a novel multiplex one-step real-time RT-PCR assay for detecting enterovirus and parechovirus in fecal samples?
A novel multiplex real-time RT-PCR assay provides high sensitivity and specificity for the simultaneous detection of enterovirus and parechovirus in clinical fecal samples.
INTRODUCTION: Enterovirus (EV) and parechovirus (PeV) can either infect humans asymptomatically or can cause gastroenteritis, respiratory symptoms and, sometimes, severe disease. As the number of newly identified EV and PeV genotypes keeps increasing, diagnostic methods need to be updated. To this end, we described a novel multiplex one-step real-time RT-PCR to detect EV and human PeV (HPeV) simultaneously in fecal samples collected from children with rotavirus group A (RV-A)-related gastroenteritis. METHODS: The specificity and sensitivity of the EV/HPeV realtime RT-PCR were evaluated with two 2011 Quality Control for Molecular Diagnostics (QCMD) panels for EV and HPeV detection. RNA was extracted from 111 RV-A-positive fecal samples collected from children up to 5 years of age who had been hospitalized for gastroenteritis from September 2010 to August 2011. RESULTS: The EV/HPeV real-time RT-PCR showed a 100% sensitivity and specificity for EV and 91% and 91.7% for HPeV, respectively. Of the 111 RV-A-positive stool specimens, 28 (25.2%) were EV-positive and 7 (6.3%) were HPeV-positive. No clinical differences between children with single or double infections were observed. DISCUSSION: In our study, the frequency of EV and HPeV infections was surprisingly high, thus underlining the importance of including EV and HPeV detection in diagnostic panels. The multiplex real-time RT-PCR presented in this paper can therefore be a useful method in a diagnostic setting.
No takes yet. Share an insight, caveat, or question.
Bubba et al. (2015) conducted a cross-sectional in Acute rotavirus-A related gastroenteritis (n=111). Multiplex one-step real-time RT-PCR assay was evaluated on Sensitivity and specificity of the multiplex real-time RT-PCR assay for EV and HPeV detection. A novel multiplex real-time RT-PCR assay demonstrated 100% sensitivity and specificity for enterovirus and 91% sensitivity and 91.7% specificity for human parechovirus in clinical fecal samples.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: