Key result
Left ventricular lead extraction and reimplantation in patients with CRT/CRTD infection or dysfunction achieved a 100% extraction success rate and an 87.2% reimplantation success rate.
Why the study?
The study investigated the success rate, methods, and associated complications of left ventricular lead extraction and venous pathway reimplantation in patients with a CRT or CRTD.
Cohort (n=54)
No
Answers are grounded in this paper and cite their sources.
Left ventricular lead extraction and reimplantation in patients with CRT/CRTD is feasible, demonstrating a 100% extraction success rate and an 87.2% reimplantation success rate with low complication rates.
The present study aimed to investigate the success rate, methods and associated complications of left ventricular lead (LVL) extraction and venous pathway reimplantation in patients with cardiac resynchronization therapy device/defibrillator (CRT/CRTD). A retrospective analysis was performed in the patients who underwent CRT/CRTD extraction and reimplantation at our hospital from January 2012 to October 2018. The methods, patient complications and success rate of extraction and reimplantation of LVL were analyzed. A total of 54 patients underwent CRT/CRTD removal (pacemaker infection, n=51; LVL dysfunction, n=3; CRT/CRTD, 34/20). A total of 54 LVLs were removed (3 active electrodes and 51 passive electrodes). The average implantation duration of the LVL was 53.5 months (range, 1-204 months), whereas the success rate of the LVL extraction was 100% (94% completely removed and 6% clinically removed. A total of 6 patients (11%) were treated only by manual traction, whereas the remaining patients had their LVL successfully removed using extraction tools. In the peri-operative period, one fatality occurred (2%). The highest complication rate of the lead extraction was 2% and no minor complications were observed. A total of 36 patients were reimplanted on the right side, which was successful in 31 cases (success rate, 86.1%), whereas 3 cases were successfully reimplanted on the left side. The total success rate of LVL reimplantation was 87.2%. The procedure of the LVL removal and reimplantation exhibited a high success rate and a lower incidence of complications compared with that in patients with cardiac devices.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2019) conducted a cohort in CRT/CRTD device infection or dysfunction (n=54). Left ventricular lead extraction and reimplantation was evaluated on Success rate of left ventricular lead extraction. Left ventricular lead extraction and reimplantation in patients with CRT/CRTD infection or dysfunction achieved a 100% extraction success rate and an 87.2% reimplantation success rate.
Synapse has enriched 10 related papers. Consider them for comparative context: