Key result
BAV shows similar 10-year freedom from adverse aortic events to TAV after isolated AVR.
Why the study?
This study aimed to compare long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid and tricuspid aortic valves.
Does the presence of a bicuspid aortic valve compared to a tricuspid aortic valve increase the risk of adverse aortic events and ascending aortic dilatation in patients with an ascending aorta diameter ≤ 45 mm undergoing isolated aortic valve replacement?
Cohort (n=310)
No
Does the presence of a bicuspid aortic valve compared to a tricuspid aortic valve increase the risk of adverse aortic events and ascending aortic dilatation in patients with an ascending aorta diameter ≤ 45 mm undergoing isolated aortic valve replacement?
In patients with an ascending aorta diameter ≤ 45 mm undergoing isolated surgical aortic valve replacement, bicuspid aortic valve morphology is not associated with increased long-term ascending aortic dilation or adverse aortic events compared to tricuspid aortic valve morphology, supporting a conservative surgical approach to the ascending aorta in these patients.
Answers are grounded in this paper and cite their sources.
No excess aortic events in BAV after isolated AVR; leaves open whether guidelines should liberalize aortic thresholds.
OBJECTIVES: The aims of the present study were to compare the long-term outcomes for ascending aortic dilatation and adverse aortic events after isolated aortic valve replacement between patients with bicuspid aortic valve (BAV) and tricuspid aortic valve ( TAV). METHODS: This retrospective study included 310 patients who had undergone isolated aortic valve replacement with an ascending aorta diameter ≤ 45 mm between January 2010 and September 2021. The patients were divided into BAV group (n=90) and TAV group (n=220). The differences in the dilation rate of the ascending aorta and long-term outcomes were analyzed. RESULTS: Overall survival was 89 ± 4% in the BAV group vs. 75 ± 6% in the TAV group at 10 years postoperatively (P=0.007), yet this difference disappeared after adjusting exclusively for age (P=0.343). The mean annual growth rate of the ascending aorta was similar between the two groups during follow-up (0.5 ± 0.6 mm/year vs. 0.4 ± 0.5 mm/year; P=0.498). Ten-year freedom from adverse aortic events was 98.1% in the BAV group vs. 95.0% in the TAV group (P=0.636). Multivariable analysis revealed preoperative ascending aorta diameter to be a significant predictor of adverse aortic events (hazard ratio: 1.76; 95% confidence interval: 1.33 to 2.38; P<0.001). CONCLUSION: Our study revealed that the long-term survival and the risks of adverse aortic events between BAV and TAV patients were similar after isolated aortic valve replacement. BAV was not a risk factor of adverse aortic events.
No takes yet. Share an insight, caveat, or question.
Zheng et al. (2024) conducted a cohort in Aortic valve disease (aortic regurgitation or aortic stenosis) undergoing isolated aortic valve replacement (n=310). Bicuspid aortic valve (BAV) morphology vs. Tricuspid aortic valve (TAV) morphology was evaluated on 10-year freedom from adverse aortic events (occurrence of aortic dissection or rupture, aortic-related death, or need for proximal aortic surgery) (HR 0.88, 95% CI 0.25-2.79, p=0.636). Bicuspid aortic valve patients had similar 10-year freedom from adverse aortic events compared to tricuspid aortic valve patients after isolated AVR.
Synapse has enriched 10 related papers. Consider them for comparative context: