Key result
Permanent placement of an implantable hemodynamic monitor in 148 symptomatic heart failure patients was technically feasible, with acceptable pressure waveforms in all but two patients.
Why the study?
Is the permanent placement of an implantable hemodynamic monitor technically feasible and safe in patients with symptomatic heart failure?
Observational (n=148)
Is the permanent placement of an implantable hemodynamic monitor technically feasible and safe in patients with symptomatic heart failure?
Permanent placement of an implantable hemodynamic monitor in symptomatic heart failure patients is technically feasible with an acceptable safety profile.
Answers are grounded in this paper and cite their sources.
Implantable hemodynamic monitor placement appears feasible in symptomatic HF; hypothesis-generating for safety and outcomes in larger prospective trials.
INTRODUCTION: Management of congestive heart failure is a serious public health problem. The use of implantable hemodynamic monitors (IHMs) may assist in this management by providing continuous ambulatory filling pressure status for optimal volume management. METHODS AND RESULTS: The Chronicle system includes an implanted monitor, a pressure sensor lead with passive fixation, an external pressure reference (EPR), and data retrieval and viewing components. The tip of the lead is placed near the right ventricular outflow tract to minimize risk of sensor tissue encapsulation. Implant technique and lead placement is similar to that of a permanent pacemaker. After the system had been successfully implanted in 148 patients, the type and frequency of implant-related adverse events were similar to a single-chamber pacemaker implant. R-wave amplitude was 15.2 +/- 6.7 mV and the pressure waveform signal was acceptable in all but two patients in whom presence of artifacts required lead repositioning. Implant procedure time was not influenced by experience, remaining constant throughout the study. CONCLUSION: Based on this evaluation, permanent placement of an IHM in symptomatic heart failure patients is technically feasible. Further investigation is warranted to evaluate the use of the continuous hemodynamic data in management of heart failure patients.
No takes yet. Share an insight, caveat, or question.
Steinhaus et al. (2005) conducted an observational in Symptomatic heart failure (n=148). Implantable hemodynamic monitor (Chronicle system) was evaluated on Implant feasibility and adverse events. Permanent placement of an implantable hemodynamic monitor in 148 symptomatic heart failure patients was technically feasible, with acceptable pressure waveforms in all but two patients.