Answers are grounded in this paper and cite their sources.
Etch rates of aluminum and "native aluminum oxide" films were studied as a function of substrate temperature in a parallel plate plasma etcher using and plasmas. Differences in the inhibition period for vs. etching were attributed to the relative abilities of these etchants to scavenge oxygen and water vapor and to etch native aluminum oxide. The temperature dependence of the etch rates suggested basic differences in the rate‐controlling steps for vs. plasma etching. The surface chemistry of the electrode materials played an important role in the etch rates observed with and .
No takes yet. Share an insight, caveat, or question.
Tokunaga et al. (1981) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: