Why the study?
Does the rebreathing technique accurately estimate arterial CO2 tension compared to direct measurement in patients with heart or lung disease?
Does the rebreathing technique accurately estimate arterial CO2 tension compared to direct measurement in patients with heart or lung disease?
The rebreathing technique provides a reasonably accurate non-invasive estimation of arterial CO2 tension in patients with heart or lung disease.
Answers are grounded in this paper and cite their sources.
May support non-invasive PaCO2 estimation in heart/lung disease; leaves open prospective validation before routine use.
It has been shown that the mixed venous CO2 tension can be determined by a rebreathing technique, using rapid infrared CO2 analysis. Theoretical analysis by Suskind and Rahn indicates that the arteriovenous CO2 tension difference is reasonably constant regardless of the cardiac output. Therefore it should be possible to estimate the arterial CO2 tension once the mixed venous tension is determined. This hypothesis was investigated in a group of 60 consecutive patients with heart or lung disease. Many of the patients had severe pulmonary emphysema with CO2 retention. The end-tidal and mixed venous CO2 tensions were determined. A constant arteriovenous CO2 tension difference of 6 mm Hg was assumed in all cases and the arterial Pco2 calculated. The deviation by this method, from directly measured arterial CO2 tension averaged +0.2 mm Hg with a standard deviation of 2.9 mm Hg (maximum errors observed ±5.3 mm Hg).
No takes yet. Share an insight, caveat, or question.
Hackney et al. (1958) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: