Key result
The T vector velocity parameter Tr40c differentiated pure potassium channel blocking drugs from multichannel blocking drugs with an AUC of 0.90, significantly outperforming J-Tpeakc.
Why the study?
New ECG biomarkers were needed to assess drug effects on ventricular repolarization and bridge the gap between the surface ECG and myocardial cellular processes.
Does T vector velocity (TVV) analysis improve the differentiation of pure potassium channel blocking drugs from multichannel blocking drugs compared to J-Tpeakc?
Does T vector velocity (TVV) analysis improve the differentiation of pure potassium channel blocking drugs from multichannel blocking drugs compared to J-Tpeakc?
T vector velocity (TVV) analysis, specifically the Tr40c parameter, significantly improves the differentiation of pure potassium channel blockers from multichannel blockers compared to traditional ECG biomarkers like J-Tpeakc, enhancing proarrhythmic risk assessment.
Answers are grounded in this paper and cite their sources.
Tr40c enhances proarrhythmic risk assessment in drug development; extends ECG biomarkers beyond J-Tpeakc in RCTs.
BACKGROUND: We present a new family of ECG biomarkers for assessing drug effects on ventricular repolarization. We show that drugs blocking inward (depolarizing) ion currents cause a relative increase of the T vector velocity (TVV) and accelerate repolarization, while drugs blocking outward ion currents cause a relative decrease of the TVV and delay repolarization. The results suggest a link between the TVV and the instantaneous change of the cellular action potentials that may contribute to bridge the gap between the surface ECG and myocardial cellular processes. METHODS: We measure TVV as the time required to reach X% of the total Trajectory length of the T vector loop, denoted as TrX. Applied to data from two FDA funded studies (22+22 subjects, 5232+4208 ECGs) which target ECG effects of various ion-channel blocking drugs, the TrX effect profiles indicate increasingly delayed electrical activity over the entire repolarization process for drugs solely reducing outward potassium current (dofetilide, moxifloxacin). For drugs eliciting block of the inward sodium or calcium currents (mexiletine, lidocaine), the TrX effect profiles were consistent with accelerated electrical activity in the initial repolarization phase. For multichannel blocking drugs (ranolazine) or drug combinations blocking multiple ion currents (dofetilide + mexiletine, dofetilide + lidocaine), the overall TrX effect profiles indicate a superposition of the individual TrX effect profiles. RESULTS: The parameter Tr40c differentiates pure potassium channel blocking drugs from multichannel blocking drugs with an area under the ROC curve (AUC) of 0.90, CI = [0.88 to 0.92]. This is significantly better than the performance of J-Tpeakc (0.81, CI = [0.78 to 0.84]) identified as the best parameter in the second FDA study. Combining the ten parameters Tr10c to Tr100c in a logistic regression model further improved the AUC to 0.94, CI = [0.92 to 0.96]. CONCLUSIONS: TVV analysis substantially improves assessment of drug effects on cardiac repolarization, providing a plausible and improved mechanistic link between drug effects on ionic currents and overall ventricular repolarization reflected in the body surface ECG. TVV contributes to an enhanced appraisal of the proarrhythmic risk of drugs beyond QTc prolongation and J-Tpeakc.
No takes yet. Share an insight, caveat, or question.
Bystricky et al. (2019) studied Healthy subjects (n=44). T vector velocity (TVV) parameter Tr40c vs. J-Tpeakc was evaluated on Differentiation of pure potassium channel blocking drugs from multichannel blocking drugs (AUC) (AUC 0.90, 95% CI 0.88-0.92). The T vector velocity parameter Tr40c differentiated pure potassium channel blocking drugs from multichannel blocking drugs with an AUC of 0.90, significantly outperforming J-Tpeakc.
Synapse has enriched 10 related papers. Consider them for comparative context: