Key result
A well plate microfluidic system was developed and successfully used to investigate dynamic platelet behavior in vitro under normal and pathological (20-200 dyn/cm2) shear loads.
The well plate microfluidic system provides a high-throughput, low-volume method for studying platelet behavior under physiological and pathological shear stress in vitro.
Answers are grounded in this paper and cite their sources.
May enable high-throughput platelet studies under shear; leaves open clinical translation pending validation.
The study of platelet behavior in real-time under controlled shear stress offers insights into the underlying mechanisms of many vascular diseases and enables evaluation of platelet-focused therapeutics. The two most common methods used to study platelet behavior at the vessel wall under uniform shear flow are parallel plate flow chambers and cone-plate viscometers. Typically, these methods are difficult to use, lack experimental flexibility, provide low data content, are low in throughput, and require large reagent volumes. Here, we report a well plate microfluidic (WPM)-based system that offers high throughput, low reagent consumption, and high experimental flexibility in an easy to use well plate format. The system consists of well plates with an integrated array of microfluidic channels, a pneumatic interface, an automated microscope, and software. This WPM system was used to investigate dynamic platelet behavior under shear stress. Multiple channel designs are presented and tested for shear loads with whole blood to determine their applicability to study thrombus formation. Normal physiological shear (0.1-20 dyn/cm(2) ) and pathological shear (20-200 dyn/cm(2) ) devices were used to study platelet behavior in vitro under various shear, matrix coating, and monolayer conditions. The high physiological relevance, low blood consumption, and increased throughput create a valuable technique available to vascular biology researchers. The approach also has extensibility to other research areas including inflammation, cancer biology, and developmental/stem cell research.
No takes yet. Share an insight, caveat, or question.
Conant et al. (2011) studied Vascular diseases and thrombus formation. Well plate microfluidic (WPM)-based system was evaluated on Dynamic platelet behavior under shear stress. A well plate microfluidic system was developed and successfully used to investigate dynamic platelet behavior in vitro under normal and pathological (20-200 dyn/cm2) shear loads.
Synapse has enriched 10 related papers. Consider them for comparative context: