Key result
In rats undergoing ECG-gated 18F-FDG PET, end-diastolic volume significantly increased with higher numbers of frames per cardiac cycle (from 353.8 μl at 4 frames to 444.8 μl at 16 frames).
Why the study?
The study aimed to investigate the impact of frame numbers per cardiac cycle in preclinical ECG-gated 18 F-FDG PET on systolic and diastolic LV functional parameters in rats.
Does the number of frames per cardiac cycle in ECG-gated 18F-FDG PET affect the measurement of LV systolic and diastolic functional parameters in rats?
Does the number of frames per cardiac cycle in ECG-gated 18F-FDG PET affect the measurement of LV systolic and diastolic functional parameters in rats?
In small animal ECG-gated PET, the number of frames per cardiac cycle significantly affects the measurement of cardiac functional parameters, necessitating consistent frame numbers for accurate comparisons.
Frame count influences LV parameters in rat FDG-PET; leaves open optimal protocols for preclinical cardiac imaging.
Objectives. This study is aimed at investigating the impact of frame numbers in preclinical electrocardiogram- (ECG-) gated 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography (PET) on systolic and diastolic left ventricular (LV) parameters in rats. Methods. 18 F-FDG PET imaging using a dedicated small animal PET system with list mode data acquisition and continuous ECG recording was performed in diabetic and control rats. The list-mode data was sorted and reconstructed with different numbers of frames (4, 8, 12, and 16) per cardiac cycle into tomographic images. Using an automatic ventricular edge detection software, left ventricular (LV) functional parameters, including ejection fraction (EF), end-diastolic (EDV), and end-systolic volume (ESV), were calculated. Diastolic variables (time to peak filling (TPF), first third mean filling rate (1/3 FR), and peak filling rate (PFR)) were also assessed. Results. Significant differences in multiple parameters were observed among the reconstructions with different frames per cardiac cycle. EDV significantly increased by numbers of frames (353.8 ± 57.7 μl[Formula: see text], 380.8 ± 57.2 μl[Formula: see text], 398.0 ± 63.1 μl[Formula: see text], and 444.8 ± 75.3 μl at 4, 8, 12, and 16 frames, respectively; [Formula: see text] vs. 16 frames), while systolic (EF) and diastolic (TPF, 1/3 FR and PFR) parameters were not significantly different between 12 and 16 frames. In addition, significant differences between diabetic and control animals in 1/3 FR and PFR in 16 frames per cardiac cycle were observed ([Formula: see text]), but not for 4, 8, and 12 frames. Conclusions. Using ECG-gated PET in rats, measurements of cardiac function are significantly affected by the frames per cardiac cycle. Therefore, if you are going to compare those functional parameters, a consistent number of frames should be used.
No takes yet. Share an insight, caveat, or question.
Eissler et al. (2021) studied Diabetic and control rats. Number of frames per cardiac cycle (4, 8, 12, and 16) vs. Different frame numbers was evaluated on Left ventricular functional parameters including EDV, ESV, EF, TPF, 1/3 FR, and PFR. In rats undergoing ECG-gated 18F-FDG PET, end-diastolic volume significantly increased with higher numbers of frames per cardiac cycle (from 353.8 μl at 4 frames to 444.8 μl at 16 frames).