Key result
Tourniquet deflation transiently increased CO2 output by 80% and O2 uptake by 55% at 2 minutes, with the magnitude of increase dependent on tourniquet inflation time.
Why the study?
Does tourniquet deflation alter O2 uptake, CO2 output, blood pressure, and heart rate in patients undergoing lower extremity orthopaedic surgery?
Observational (n=23)
Does tourniquet deflation alter O2 uptake, CO2 output, blood pressure, and heart rate in patients undergoing lower extremity orthopaedic surgery?
Tourniquet deflation during lower extremity orthopaedic surgery causes transient but significant increases in CO2 output and O2 uptake, which are proportional to the duration of inflation.
Answers are grounded in this paper and cite their sources.
May prompt closer ventilatory monitoring at deflation; extends duration-dependent metabolic observations but leaves outcome effects open.
We examined changes in O2 uptake, CO2 output, blood pressure and heart rate following tourniquet deflation in 23 patients undergoing orthopaedic surgery of the lower extremities. A pneumatic tourniquet was applied for periods ranging from 21 to 106 min (mean 51 min). Prerelease values of VO2 (O2 uptake at each min) and VCO2 (CO2 output at each min) were 201 (37) and 174 (38) (mean (SD)) ml.min-1, respectively. Significantly, VO2 and VCO2 increased by 55% and 80%, respectively, at 2 min after tourniquet release and returned to prerelease values within 8 min. The blood pressure fell significantly and the heart rate rose significantly. The increases in CO2 output and O2 uptake were dependent on the length of tourniquet inflation time; Y = 4.7 x (tourniquet time) + 54, r = 0.88, (p less than 0.001) for CO2, and Y = 1.3 x (tourniquet time) + 99, r = 0.52, (p less than 0.05) for O2. The slope of the increase in CO2 output as a function in inflation time was 3.6 times greater than that of O2 uptake. In conclusion, CO2 output and O2 uptake increased transiently after tourniquet deflation and the extent of the increase in CO2 output is more than threefold as compared with that in O2 uptake.
No takes yet. Share an insight, caveat, or question.
Hoka et al. (1992) conducted an observational in Orthopaedic surgery of the lower extremities (n=23). Tourniquet deflation vs. Prerelease values (baseline) was evaluated on Changes in O2 uptake (VO2) and CO2 output (VCO2). Tourniquet deflation transiently increased CO2 output by 80% and O2 uptake by 55% at 2 minutes, with the magnitude of increase dependent on tourniquet inflation time.