Key result
Tourniquet application during knee surgery increased mean arterial pressure by 26% during inflation and cardiac index by 40% after deflation.
Why the study?
Does tourniquet application alter hemodynamic and metabolic parameters in young men undergoing knee surgery?
Observational (n=10)
Does tourniquet application alter hemodynamic and metabolic parameters in young men undergoing knee surgery?
Tourniquet application during knee surgery induces significant but transient hemodynamic and metabolic changes, which may be clinically relevant in patients with concomitant cardiovascular diseases.
Answers are grounded in this paper and cite their sources.
Tourniquet use was associated with transient hemodynamic shifts; leaves open relevance to outcomes in patients with cardiovascular disease.
We evaluated the effects of tourniquet application on the cardiovascular system and metabolism in 10 young men undergoing knee surgery with general anesthesia. The duration of inflation was from 75 to 108 min. Heart rate, mean arterial pressure, cardiac index (CI) by pulse contour method, and systemic vascular resistance were measured before, during, and after tourniquet inflation. pH, Pao2, Paco2, and lactate blood concentrations were also measured. V̇o2 and V̇co2 were assessed every minute from tracheal intubation up to 15 min after tourniquet deflation and V̇o2 in excess of the basal value over the 15 min after deflation (V̇o2exc) was calculated. Mean arterial pressure increased 26% (P < 0.05) during inflation and returned to basal values after deflation. CI did not change immediately after inflation; although, thereafter, it increased 18% (P < 0.05). Five minutes after deflation, CI further increased to a value 40% higher than the basal value. Therefore, systemic vascular resistance increased 20% suddenly after inflation (P < 0.05) and decreased 18% after deflation (P < 0.05). V̇o2 and V̇co2 remained stable during inflation and increased (P < 0.05) after deflation. V̇o2exc depended on duration of tourniquet inflation time (Tisch) (P < 0.05). After deflation, Paco2 and lactate increased (P < 0.05) while Tisch increased. We conclude that tourniquet application induces modifications of the cardiovascular system and metabolism, which depend on tourniquet phase and on Tisch. Whether these modifications could be relevant in patients with poor physical conditions is not known. Implications The clinical effects of tourniquet application were evaluated in 10 young men undergoing knee surgery. Our data indicate that tourniquet application causes hemodynamic and metabolic changes which may become clinically relevant after a long period of tourniquet inflation, particularly in patients with concomitant cardiovascular diseases.
No takes yet. Share an insight, caveat, or question.
Girardis et al. (2000) conducted an observational in Knee surgery (n=10). Tourniquet application vs. Basal values (before inflation) was evaluated on Hemodynamic and metabolic changes (mean arterial pressure, cardiac index, systemic vascular resistance) (p=< 0.05). Tourniquet application during knee surgery increased mean arterial pressure by 26% during inflation and cardiac index by 40% after deflation.
Synapse has enriched 10 related papers. Consider them for comparative context: