Key result
Three-dimensional CEMRA volumetry exhibited a better intraclass correlation coefficient (0.95 vs 0.83-0.86) and larger percentage growth detection (4% vs 1%) than 2D diameter measurements.
Why the study?
Does 3-dimensional CEMRA volumetry improve reliability and sensitivity to growth compared to 2-dimensional diameter measurements in bicuspid aortic valve patients?
Observational (n=20)
Does 3-dimensional CEMRA volumetry improve reliability and sensitivity to growth compared to 2-dimensional diameter measurements in bicuspid aortic valve patients?
3D CEMRA volumetry is more reliable and sensitive for monitoring thoracic aortic aneurysm growth in bicuspid aortic valve patients compared to standard 2D diameter measurements.
Answers are grounded in this paper and cite their sources.
CEMRA volumetry may detect BAV aortic growth more sensitively than diameters; hypothesis-generating and requires prospective validation before practice change.
OBJECTIVES: Bicuspid aortic valve patients can develop thoracic aortic aneurysms and therefore require serial imaging to monitor aortic growth. This study investigates the reliability of contrast-enhanced magnetic resonance angiography (CEMRA) volumetry compared with 2-dimensional diameter measurements to identify thoracic aortic aneurysm growth. MATERIALS AND METHODS: A retrospective, institutional review board-approved, and Health Insurance Portability and Accountability Act-compliant study was conducted on 20 bicuspid aortic valve patients (45 ± 8.9 years, 20% women) who underwent serial CEMRA with a minimum imaging follow-up of 11 months. Magnetic resonance imaging was performed at 1.5 T with electrocardiogram-gated, time-resolved CEMRA. Independent observers measured the diameter at the sinuses of Valsalva (SOVs) and mid ascending aorta (MAA) as well as ascending aorta volume between the aortic valve annulus and innominate branch. Intraobserver/interobserver coefficient of variation (COV) and intraclass correlation coefficient (ICC) were computed to assess reliability. Growth rates were calculated and assessed by Student t test (P < 0.05, significant). The diameter of maximal growth (DMG), defined as the diameter at SOV or MAA with the faster growth rate, was recorded. RESULTS: The mean time of follow-up was 2.6 ± 0.82 years. The intraobserver COV was 0.01 for SOV, 0.02 for MAA, and 0.02 for volume (interobserver COV: 0.02, 0.03, 0.04, respectively). The ICC was 0.83 for SOV, 0.86 for MAA, 0.90 for DMG, and 0.95 for volume. Average aortic measurements at baseline and (follow-up) were 42 ± 3 mm (42 ± 3 mm, P = 0.11) at SOV, 46 ± 4 mm (47 ± 4 mm, P < 0.05) at MAA, and 130 ± 23 mL (144 ± 24 mL, P < 0.05). Average size changes were 0.2 ± 0.6 mm/y (1% ± 2%) at SOV, 0.5 ± 0.8 mm/y (1% ± 2%) at MAA, 0.7 ± 0.7 mm/y (2% ± 2%) at DMG, and 6 ± 3 mL/y (4% ± 3%) with volumetry. CONCLUSIONS: Three-dimensional CEMRA volumetry exhibited a larger effect when examining percentage growth, a better ICC, and a marginally lower COV. Volumetry may be more sensitive to growth and possibly less affected by error than diameter measurements.
No takes yet. Share an insight, caveat, or question.
Trinh et al. (2016) conducted an observational in Bicuspid aortic valve (n=20). Contrast-enhanced magnetic resonance angiography (CEMRA) volumetry vs. 2-dimensional diameter measurements was evaluated on Reliability (intraclass correlation coefficient) and growth rate. Three-dimensional CEMRA volumetry exhibited a better intraclass correlation coefficient (0.95 vs 0.83-0.86) and larger percentage growth detection (4% vs 1%) than 2D diameter measurements.