Key result
Decreased heart rate variability prior to extubation was significantly associated with extubation failure in extremely preterm infants, yielding 100% specificity and positive predictive value.
Why the study?
Does heart rate variability prior to extubation predict extubation readiness in extremely preterm infants?
Observational (n=47)
Does heart rate variability prior to extubation predict extubation readiness in extremely preterm infants?
Decreased heart rate variability prior to extubation is highly specific for predicting extubation failure in extremely preterm infants, though its sensitivity is limited.
HRV should not yet guide extubation decisions in preterm infants; leaves open prospective validation of its clinical utility.
BACKGROUND: Mechanical ventilation (MV) is associated with changes in autonomic nervous system activity in preterm infants, which can be assessed by measurements of heart rate variability (HRV). Decreased HRV has been described in adults undergoing disconnection from MV; such information is not available in preterm infants. OBJECTIVE: To compare differences in HRV between infants successfully extubated and those who failed, and to evaluate the accuracy of HRV as a predictor of extubation readiness. METHODS: This is a prospective, observational study of infants with a birth weight ≤1,250 g undergoing their first extubation attempt. Heart rate was measured during a 60-min period immediately prior to extubation and HRV was calculated using the frequency domain analysis. RESULTS: A total of 47 infants were studied; 36 were successfully extubated and 11 reintubated. There were no differences in patient demographics, ventilator settings, blood gases or postextubation management between the groups. All components of the HRV analysis were significantly decreased in infants who failed, generating high areas under the receiver operating characteristic curve. The specificity and positive predictive values were 100, but with limited sensitivity and negative predictive values. CONCLUSIONS: Infants considered 'ready to be extubated' but who subsequently failed their first extubation attempt had decreased HRV prior to extubation. Though promising, the value of HRV as a predictor of extubation readiness requires further evaluation.
No takes yet. Share an insight, caveat, or question.
Kaczmarek et al. (2013) conducted an observational in Extremely preterm infants undergoing extubation (n=47). Heart rate variability (HRV) was evaluated on Extubation readiness (successful extubation vs failure/reintubation). Decreased heart rate variability prior to extubation was significantly associated with extubation failure in extremely preterm infants, yielding 100% specificity and positive predictive value.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: