Key result
Video-based heart rate monitoring demonstrated excellent agreement with reference pulse oximetry across all skin pigmentation types during a hypoxic challenge, with a bias of -0.21 bpm and RMSD of 2.15 bpm.
Why the study?
Does video-based heart rate monitoring accurately measure heart rate compared to a reference pulse oximeter in healthy volunteers across different skin pigmentations during a hypoxic challenge?
Observational (n=10)
Does video-based heart rate monitoring accurately measure heart rate compared to a reference pulse oximeter in healthy volunteers across different skin pigmentations during a hypoxic challenge?
A motion-tolerant video-based heart rate monitoring algorithm demonstrated excellent agreement with standard pulse oximetry across a full range of skin pigmentations during acute hypoxic challenges.
Answers are grounded in this paper and cite their sources.
May enable motion-tolerant video-PPG HR monitoring in hypoxia across skin tones; leaves open validation before clinical adoption.
The robust monitoring of heart rate from the video-photoplethysmogram (video-PPG) during challenging conditions requires new analysis techniques. The work reported here extends current research in this area by applying a motion tolerant algorithm to extract high quality video-PPGs from a cohort of subjects undergoing marked heart rate changes during a hypoxic challenge, and exhibiting a full range of skin pigmentation types. High uptimes in reported video-based heart rate (HR vid ) were targeted, while retaining high accuracy in the results. Ten healthy volunteers were studied during a double desaturation hypoxic challenge. Video-PPGs were generated from the acquired video image stream and processed to generate heart rate. HR vid was compared to the pulse rate posted by a reference pulse oximeter device (HR p ). Agreement between video-based heart rate and that provided by the pulse oximeter was as follows: Bias = − 0.21 bpm, RMSD = 2.15 bpm, least squares fit gradient = 1.00 (Pearson R = 0.99, p < 0.0001), with a 98.78% reporting uptime. The difference between the HR vid and HR p exceeded 5 and 10 bpm, for 3.59 and 0.35% of the reporting time respectively, and at no point did these differences exceed 25 bpm. Excellent agreement was found between the HR vid and HR p in a study covering the whole range of skin pigmentation types (Fitzpatrick scales I–VI), using standard room lighting and with moderate subject motion. Although promising, further work should include a larger cohort with multiple subjects per Fitzpatrick class combined with a more rigorous motion and lighting protocol.
No takes yet. Share an insight, caveat, or question.
Addison et al. (2017) conducted an observational in Healthy volunteers undergoing acute hypoxic challenge (n=10). Video-based heart rate monitoring (video-PPG) vs. Reference pulse oximeter device (Nellcor N600x) was evaluated on Agreement between video-based heart rate and pulse oximeter heart rate (Bias = -0.21 bpm, RMSD = 2.15 bpm, Pearson R = 0.99, p=<0.0001). Video-based heart rate monitoring demonstrated excellent agreement with reference pulse oximetry across all skin pigmentation types during a hypoxic challenge, with a bias of -0.21 bpm and RMSD of 2.15 bpm.
Synapse has enriched 10 related papers. Consider them for comparative context: