Answers are grounded in this paper and cite their sources.
The rates of ozonolysis of a suite of terminal alkenes ranging from C(8-14) are determined in the gas phase at an elevated temperature of 395.9 ± 1.2 K and a pressure of ∼650 Torr using the EXTreme RAnge chamber (EXTRA). Rates are found to be invariant with carbon number, whilst literature measurements conducted under ambient conditions exhibited an increase in rate coefficient after 10 carbon atoms. These earlier findings appear to contradict the intuitive notion that the inductive effect is a short-range process operating over a maximum distance of a few carbon atoms. These new measurements support the hypothesis that operating under ambient conditions, kinetic measurements of condensable species can be influenced adversely by heterogeneous processes and should therefore be treated with caution.
No takes yet. Share an insight, caveat, or question.
McGillen et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: