Key result
MitraClip implantation in high surgical risk patients with moderate-to-severe or severe mitral regurgitation achieved an acute procedural success rate of 91.13% and a 30-day single leaflet device attachment rate of 1.21%.
Why the study?
Following marketing approval of the MitraClip NT System in Japan, real-world 1-year outcomes in high surgical risk patients were evaluated through post-marketing surveillance.
Does transcatheter mitral valve repair with MitraClip improve mitral regurgitation severity and functional outcomes in high surgical risk patients?
Observational (n=500)
Yes
Does transcatheter mitral valve repair with MitraClip improve mitral regurgitation severity and functional outcomes in high surgical risk patients?
In a real-world Japanese cohort of high surgical risk patients, MitraClip demonstrated high acute procedural success, durable MR reduction, and significant functional improvement at 1 year.
Answers are grounded in this paper and cite their sources.
Supports real-world MitraClip use in high-risk Japanese patients; extends trial data to this Asian cohort.
BACKGROUND: The MitraClip NT System was approved for marketing in Japan on October 31, 2017, and a prospective, multi-center, single-arm Post-Marketing use Surveillance (PMS) study was launched in 2018. This is the first report of the Japan PMS study with 1-year subject outcomes. METHODS AND RESULTS: A total of 500 patients were registered between April 2018 and January 2019. Patients with symptomatic chronic moderate-to-severe (3+) or severe mitral regurgitation (MR; 4+), MR with a Society of Thoracic Surgery (STS) replacement score of ≥8%, or presence of 1 pre-defined risk factor were enrolled. Primary outcome measures included acute procedural success (APS), and rate of Single Leaflet Device Attachment (SLDA) at 30 days. The overall cohort was elderly (77.9±9.48 years) with functional MR etiology in 71.6% of the subjects. The majority of subjects were New York Heart Association (NYHA) class III/IV (68.9%), with mean STS replacement score of 11.95±9.66%. The APS rate was 91.13% and the 30-day SLDA rate was 1.21%. Durable MR reduction was achieved with 88.1% of subjects at MR ≤2+ at 1 year. Significant improvement in the functional capacity was observed, with 93% of subjects at NYHA class I/II at 1 year. CONCLUSIONS: In the Japan PMS experience, the MitraClip procedure resulted in improvements in MR severity, with significantly improved functional outcomes. These results demonstrate safety and efficacy of MitraClip therapy in the eligible Japanese population.
No takes yet. Share an insight, caveat, or question.
A 2021 study conducted an observational in Moderate-to-severe and severe mitral regurgitation (n=500). MitraClip NT System was evaluated on Acute procedural success (APS) at discharge. MitraClip implantation in high surgical risk patients with moderate-to-severe or severe mitral regurgitation achieved an acute procedural success rate of 91.13% and a 30-day single leaflet device attachment rate of 1.21%.