Key result
Automated brachial-ankle pulse wave velocity was closely correlated with reference carotid-femoral pulse wave velocity and showed reasonable agreement in detecting increased arterial stiffness.
Why the study?
Carotid-femoral PWV is the gold standard for assessing arterial stiffness, prompting evaluation of automated brachial-ankle PWV using a professional oscillometric blood pressure monitor.
Does automated brachial-ankle PWV measurement correlate with reference carotid-femoral PWV for assessing arterial stiffness in subjects from a hypertension clinic?
Cross-Sectional (n=97)
Randomized crossover design for measurement order
No
Does automated brachial-ankle PWV measurement correlate with reference carotid-femoral PWV for assessing arterial stiffness in subjects from a hypertension clinic?
Automated baPWV measurement using an oscillometric blood pressure monitor is feasible and correlates closely with the gold standard cfPWV for assessing arterial stiffness.
Answers are grounded in this paper and cite their sources.
May support automated baPWV screening in hypertension clinics; leaves open prospective validation for risk stratification or outcomes.
Carotid-femoral pulse wave velocity (cfPWV) is the gold standard method for assessing arterial stiffness. This study evaluated automated brachial-ankle PWV (baPWV) taken by a professional oscillometric blood pressure monitor (Microlife WatchBP Office Vascular) versus reference cfPWV (Complior device). Subjects recruited from a hypertension outpatient clinic had duplicate baPWV and cfPWV measurements (randomized crossover design) and carotid ultrasonography. Of 102 subjects recruited, 101 had valid baPWV measurements. Four subjects were excluded and 97 were analyzed (age 58.3 ± 11.4 years, men 70%, hypertensives 76%, diabetics 17%, cardiovascular disease 10%, smokers 23%). The mean difference between baPWV (13.1 ± 1.8 m/s) and cfPWV (9.1 ± 1.8 m/s) was 4.0 ± 1.4 m/s (P < .01) with close association between them (r = 0.70, P < .01). baPWV and cfPWV were correlated with age (r 0.54/0.49 respectively), systolic blood pressure (0.45/0.50), carotid intima-media thickness (0.31/0.44), and carotid distensibility coefficient (-0.47/-0.34) (all P < .05; no difference between the two methods, z test). There was reasonable agreement (77%) between the two methods in identifying subjects at the top quartile of their distributions (kappa 0.39, P < .01). The areas under the receiver operating characteristic curves for the identification of carotid plaques were comparable for cfPWV and baPWV (0.79 and 0.74 respectively, P = NS). Automated baPWV measurement by a professional oscillometric blood pressure monitor is feasible and observer-independent. baPWV values differ from those by cfPWV, yet they are closely correlated, have reasonable agreement in detecting increased arterial stiffness and give similar associations with carotid stiffness and atherosclerosis.
No takes yet. Share an insight, caveat, or question.
Κόλλιας et al. (2020) conducted a cross-sectional in Hypertension and cardiovascular risk (n=97). Automated brachial-ankle pulse wave velocity (baPWV) vs. Carotid-femoral pulse wave velocity (cfPWV) was evaluated on Correlation between brachial-ankle pulse wave velocity and carotid-femoral pulse wave velocity (r = 0.70, p=<0.01). Automated brachial-ankle pulse wave velocity was closely correlated with reference carotid-femoral pulse wave velocity and showed reasonable agreement in detecting increased arterial stiffness.
Synapse has enriched 10 related papers. Consider them for comparative context: