Key result
Radiofrequency ablation using the Cartosound system was feasible and safe for treating incessant ventricular tachycardia in a patient with a chronic apical left ventricular thrombus.
Case Report (n=1)
The Cartosound system can be safely used to guide radiofrequency ablation in patients with intracardiac thrombus to avoid catheter-induced complications.
Answers are grounded in this paper and cite their sources.
May enable VT ablation in select LV thrombus cases; hypothesis-generating and should not yet change practice.
We describe the case of a young man suffering from incessant ventricular tachycardia and a chronic apical left ventricular thrombus. We performed radiofrequency ablation of this tachycardia emerging from the border zone of the septoapical anevrism, near the apical thrombus. We used Cartosound system to avoid manipulation of catheter in the thrombus. We demonstrate, in this case, that the technique is feasible and safe.
No takes yet. Share an insight, caveat, or question.
Raczka et al. (2010) conducted a case report in Incessant ventricular tachycardia and chronic apical left ventricular thrombus (n=1). Radiofrequency ablation using Cartosound system was evaluated on Feasibility and safety. Radiofrequency ablation using the Cartosound system was feasible and safe for treating incessant ventricular tachycardia in a patient with a chronic apical left ventricular thrombus.