Key result
The proposed continuous blood pressure measurement system based on pulse wave velocity improved the accuracy of blood pressure measurements by 58% compared to the original method.
Effect estimate: improved by 58%
A novel continuous blood pressure measurement system using pulse wave and ECG signals improved measurement accuracy by 58% and met AAMI standards.
May advance continuous BP monitoring feasibility; leaves open prospective clinical validation before practice adoption.
With increasingly fierce competition for jobs, the pressures on people have risen in recent years, leading to lifestyle and diet disorders that result in significantly higher risks of cardiovascular disease. Hypertension is one of the common chronic cardiovascular diseases; however, mainstream blood pressure measurement devices are relatively heavy. When multiple measurements are required, the user experience and the measurement results may be unsatisfactory. In this paper, we describe the design of a signal collection module that collects pulse waves and electrocardiograph (ECG) signals. The collected signals are input into a signal processing module to filter the noise and amplify the useful physiological signals. Then, we use a wavelet transform to eliminate baseline drift noise and detect the feature points of the pulse waves and ECG signals. We propose the concept of detecting the wave shape associated with an instance, an approach that minimizes the impact of atypical pulse waves on blood pressure measurements. Finally, we propose an improved method for measuring blood pressure based on pulse wave velocity that improves the accuracy of blood pressure measurements by 58%. Moreover, the results meet the american medical instrument promotion association standards, which demonstrate the feasibility of our measurement system.
No takes yet. Share an insight, caveat, or question.
Its licence doesn't allow us to show a copy here.
Li et al. (2018) studied Blood pressure measurement (n=15). Continuous blood pressure measurement system based on pulse wave and ECG signals vs. Original pulse wave velocity measurement method was evaluated on Accuracy of blood pressure measurement (improved by 58%). The proposed continuous blood pressure measurement system based on pulse wave velocity improved the accuracy of blood pressure measurements by 58% compared to the original method.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: