Key result
Electrical cardioversion in patients receiving nontoxic doses of digitalis resulted in 0 cases of ventricular tachycardia and no consistent increase in ventricular ectopy.
Why the study?
Does electrical cardioversion increase ventricular ectopy in patients receiving nontoxic doses of digitalis?
Observational (n=21)
Does electrical cardioversion increase ventricular ectopy in patients receiving nontoxic doses of digitalis?
Electrical cardioversion appears safe and does not increase ventricular ectopy in patients on digoxin without clinical toxicity, even with modestly elevated serum levels.
Answers are grounded in this paper and cite their sources.
May support cardioversion safety in nontoxic digitalis patients; hypothesis-generating and leaves open prospective confirmation.
To ascertain whether electrical cardioversion increases ventricular ectopy in patients receiving nontoxic doses of digitalis, we recorded continuous electrocardiograms in 21 patients for at least 1 hour before and immediately after direct-current countershock. Seventeen patients also received specific antiarrhythmic therapy. There were no consistent differences in the frequency of severity of ventricular ectopy before and after cardioversion despite a wide range of serum digoxin levels (0.1 to 3.0 ng/mL; mean, 1.6 ng/mL). No patient had ventricular tachycardia after cardioversion, and all eight patients with serum digoxin levels greater than 2.0 ng/mL had the same or fewer ventricular ectopic beats per hour and the same or lower ectopy grades after cardioversion when pre- and postshock recordings were compared. These findings suggest that patients receiving digoxin without clinical evidence of digitalis toxicity are at low risk for serious postcardioversion ventricular arrhythmias, even when serum digoxin levels are modestly elevated. The extent to which this low risk is due to concomitant antiarrhythmic therapy is unknown
No takes yet. Share an insight, caveat, or question.
Roy V. Ditchey (1981) conducted an observational in Patients receiving nontoxic doses of digitalis undergoing electrical cardioversion (n=21). Electrical cardioversion vs. Pre-cardioversion baseline was evaluated on Frequency and severity of ventricular ectopy. Electrical cardioversion in patients receiving nontoxic doses of digitalis resulted in 0 cases of ventricular tachycardia and no consistent increase in ventricular ectopy.
Synapse has enriched 10 related papers. Consider them for comparative context: