We study the humidity dependence of the generated current of Pt/TiO 2 /Ti electromotive force (emf) cells by means of microcalorimetry, current–voltage ( I – V ) characteristics, and electrochemical impedance spectroscopy. We prepare TiO 2 with a high-voltage electrochemical anodization and the Pt electrode via a paste process. We find that short-circuit current densities ( J sc ) significantly vary by adding water vapor to the 2.1 vol % hydrogen-in-air mixture used to generate the emf, while the open-circuit voltage ( V oc ) always increases with increasing relative humidity (RH). J sc increases from 8.2 mA/cm 2 (RH = 0%) to a maximum value of 9.4 mA/cm 2 (RH = 10%). At RH > 10%, J sc decreases slightly. The increase in J sc is interpreted as enhanced electron transport as a consequence of the interaction of water with TiO 2, while the decrease in J sc seems to be related to a large amount of water negatively affecting the rate-determining step for emf.
No takes yet. Share an insight, caveat, or question.
Cakabay et al. (2016) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: