Key result
Higher LVA-Disc linked to ~110% increased arrhythmia recurrence risk per 0.5-unit rise after redo ablation.
Why the study?
Voltage-defined low-voltage areas provide an electrical phenotype of atrial cardiomyopathy, but the relationship between unipolar and bipolar LVA extent and arrhythmia recurrence after redo ablation is unclear.
Cohort (n=160)
No
Answers are grounded in this paper and cite their sources.
In patients undergoing redo AF ablation, a higher unipolar-bipolar LVA-Disc was independently associated with post-blanking arrhythmia recurrence, suggesting combined mapping improves atrial substrate assessment over absolute LVA burden alone.
No abstract yet. The journal hasn't published one we can show.
No takes yet. Share an insight, caveat, or question.
Mohsen et al. (2026) conducted a cohort in Paroxysmal or persistent atrial fibrillation (n=160). Normalized unipolar-bipolar LVA extent-difference index (LVA-Disc) was evaluated on Post-blanking arrhythmia recurrence (AR) (HR 2.100, 95% CI 1.637-2.695, p=<0.001). Each 0.5-unit increase in total LVA-Disc was independently associated with a higher hazard of post-blanking arrhythmia recurrence in patients undergoing redo ablation.