Key result
Repeated balloon inflation during angioplasty fails to show progressive ischemic adaptation or reliable ischemic preconditioning.
Why the study?
Does repeated balloon inflation during angioplasty induce ischemic preconditioning and collateral recruitment in patients with single vessel coronary artery disease?
Observational (n=20)
No
Does repeated balloon inflation during angioplasty induce ischemic preconditioning and collateral recruitment in patients with single vessel coronary artery disease?
Repeated balloon angioplasty does not consistently demonstrate progressive ischemic preconditioning, and collateral circulation recruitment is not the primary mechanism for the observed decrease in ST elevation during subsequent inflations.
Challenges repeated balloon inflation as a reliable ischemic preconditioning model; leaves open alternative mechanisms for ST changes in single-vessel disease.
Reevaluation of repeated balloon angioplasty as a model of ischemic preconditioning and of the role of collateral circulation and high-frequency electrocardiograms in repeated inflations was carried out. There have been few studies using angioplasty as a model of ischemic preconditioning of the collateral circulation during repeated inflations or of the use of high-frequency electrocardiograms during angioplasty. Twenty patients underwent 3 repeated balloon inflations, each with a duration of more than 138 seconds. During inflation, ipsilateral and contralateral coronary angiography and signal-averaged electrocardiography were performed. At the 1st inflation, the ST segment gradually increased as the inflation time elapsed. During the 2nd and 3rd inflations, in which ST elevation was nearly equal, the ST segment gradually increased, but it was not as prominent as that at the 1st inflation; thus, the concept that ischemia is gradually ameliorated (adaptation to ischemia) was not documented. Comparison of the maximal ST elevation and ipsilateral and contralateral circulation at each inflation revealed that the ST segment became elevated and the contralateral collateral circulation increased significantly at the 1st inflation compared with those in the control. ST elevation, however decreased significantly and collateral circulation remained unchanged at the 2nd inflation; thus, collateral circulation did not cause the ST elevation decrease. The total root mean square voltage detected by signal averaging decreased significantly only at the 1st inflation. Balloon angioplasty is not always suitable as a model of ischemic preconditioning and collateral circulation is not the cause of ischemic preconditioning.
No takes yet. Share an insight, caveat, or question.
Sasaki et al. (1995) conducted an observational in Single vessel coronary artery disease (n=20). Repeated balloon inflation vs. 1st inflation was evaluated on Maximal ST segment elevation and collateral circulation during repeated inflations (p=<0.05). Repeated balloon inflation during angioplasty did not demonstrate progressive adaptation to ischemia, indicating it is not always a suitable model for ischemic preconditioning and that collateral circulation is not its cause.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: