Key result
Implantation of central flow valves in patients with advanced valvular heart disease had an operative mortality rate of 3.9%, with most deaths related to low output syndrome.
Observational (n=153)
Answers are grounded in this paper and cite their sources.
In patients undergoing central flow valve implantation for advanced valvular heart disease, preoperative right ventricular end-diastolic pressure >15 mmHg and tricuspid regurgitation strongly predict postoperative low output syndrome.
The pathophysiology of advanced valvular heart disease and its clinical implications were analyzed. The study was undertaken primarily on 153 recent patients with implantation of central flow valves. The operative mortality rate was 3.9%, with deaths except one related to LOS. There was a higher incidence of LOS in left ventricular volume-overloaded hearts, and a much higher incidence in patients associated with TR: 70% of TR cases with RVEDP higher than 15 mmHg developed LOS. Cardiac contractile reserve proved to be useful index for predicting immediate postoperative and long-term results; less favorable results were indicated in patients with PWE below 10 mm even after epinephrine infusion. In volume-overloaded hearts, the muscle cell diameter of the left ventricle increased proportionally to the dimension of the left ventricle, with interstitial fibrosis representing irreversible morphological change. Patients with a prolonged indocyanine green disappearance rate showed fibrosis of the liver and were complicated more frequently by LOS, hepatic and renal disturbance and increased mortality. Patients with cardiac cachexia were liable to develop LOS postoperatively, and preoperative GIK therapy appeared to be effective in improving depressed metabolism and hemodynamics, except in patients with severe TR.
No takes yet. Share an insight, caveat, or question.
Eguchi et al. (1984) conducted an observational in Advanced valvular heart disease (n=153). Implantation of central flow valves was evaluated on Operative mortality. Implantation of central flow valves in patients with advanced valvular heart disease had an operative mortality rate of 3.9%, with most deaths related to low output syndrome.
Synapse has enriched 10 related papers. Consider them for comparative context: